The response of the human circulatory system to an acute 200-μT, 60-Hz magnetic field exposure
- PMID: 20496180
- DOI: 10.1007/s00420-010-0543-1
The response of the human circulatory system to an acute 200-μT, 60-Hz magnetic field exposure
Abstract
Purpose: Recent research by the authors on the effects of extremely low-frequency (ELF) magnetic field (MF) exposure on human heart rate (HR), heart rate variability (HRV), and skin blood perfusion found no cardiovascular effects of exposure to an 1,800-μT, 60-Hz MF. Research from our group using rats, however, has suggested a microcirculatory response to a 200-μT, 60-Hz MF exposure. The present pilot study investigated the effects of 1 h of exposure to a 200-μT, 60-Hz MF on the human circulation. Microcirculation (as skin blood perfusion) and HR were measured using laser Doppler flowmetry. Mean arterial pressure was monitored with a non-invasive blood pressure system.
Methods: Ten volunteers were recruited to partake in a counterbalanced, single-blinded study consisting of two testing sessions (real and sham exposure) administered on separate days. Each session included four consecutive measurement periods separated by rest, allowing assessment of cumulative and residual MF effects.
Results: A within-subjects analysis of variance did not reveal session by time period interactions for any of the parameters which would have been suggestive of a MF effect (p > 0.05). Perfusion, HR, and skin surface temperature decreased over the course of the experiment (p < 0.05).
Conclusions: The MF used in this experiment did not affect perfusion, HR, or mean arterial pressure. Decreasing perfusion and HR trends over time were similar to our previous results and appear to be associated with a combination of inactivity (resulting in decreasing body temperatures) and reduced physiological arousal.
Similar articles
-
The cardiovascular response to an acute 1800-microT, 60-Hz magnetic field exposure in humans.Int Arch Occup Environ Health. 2010 Apr;83(4):441-54. doi: 10.1007/s00420-009-0484-8. Epub 2009 Nov 10. Int Arch Occup Environ Health. 2010. PMID: 19902234
-
Effects of a static magnetic field of either polarity on skin microcirculation.Microvasc Res. 2005 Jan;69(1-2):24-7. doi: 10.1016/j.mvr.2004.11.002. Microvasc Res. 2005. PMID: 15797257
-
Effects of permanent magnets on resting skin blood perfusion in healthy persons assessed by laser Doppler flowmetry and imaging.Bioelectromagnetics. 2001 Oct;22(7):494-502. doi: 10.1002/bem.78.abs. Bioelectromagnetics. 2001. PMID: 11568935
-
Human electrophysiological and cognitive effects of exposure to ELF magnetic and ELF modulated RF and microwave fields: a review of recent studies.Bioelectromagnetics. 2002 Feb;23(2):144-57. doi: 10.1002/bem.107. Bioelectromagnetics. 2002. PMID: 11835261 Review.
-
A literature review: the effects of magnetic field exposure on blood flow and blood vessels in the microvasculature.Bioelectromagnetics. 2007 Feb;28(2):81-98. doi: 10.1002/bem.20284. Bioelectromagnetics. 2007. PMID: 17004242 Review.
Cited by
-
Impact of a Generated Magnetic Field at the Schumann Resonance Frequency on Skin Blood Perfusion and Peripheral Pulse Amplitudes.Cureus. 2025 Apr 29;17(4):e83182. doi: 10.7759/cureus.83182. eCollection 2025 Apr. Cureus. 2025. PMID: 40443615 Free PMC article.
-
A 50 Hz magnetic field affects hemodynamics, ECG and vascular endothelial function in healthy adults: A pilot randomized controlled trial.PLoS One. 2021 Aug 5;16(8):e0255242. doi: 10.1371/journal.pone.0255242. eCollection 2021. PLoS One. 2021. PMID: 34351946 Free PMC article. Clinical Trial.
References
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical