Continuous direct measurement of intracellular chloride and pH in frog skeletal muscle
- PMID: 20501
- PMCID: PMC1353546
- DOI: 10.1113/jphysiol.1977.sp011983
Continuous direct measurement of intracellular chloride and pH in frog skeletal muscle
Abstract
1. Ion-sensitive electrodes (made with a chloride-sensitive ion-exchange resin) were used to measure the internal chloride activity (a(i) (Cl)) of frog sartorius fibres at 25 degrees C.2. The internal pH (pH(i)) of other sartorius fibres was measured with a recessed tip pH-sensitive electrode (made with pH-sensitive glass).3. In normal bicarbonate-free solution (containing 2.5 mM potassium), the average chloride equilibrium potential, E(Cl) (calculated from a(i) (Cl) and the measured chloride activity of the external solution (a(o) (Cl)) was 87.7 +/- 1.7 mV (mean +/- S.E.; n = 16) in fibres where the average membrane potential, E(m), was 88.3 +/- 1.5 mV (mean +/- S.E.; n = 16). In experiments where a(i) (Cl) was varied between about 1 and 10 mM (which corresponds to values of E(m) between about -105 and -50 mV) E(Cl) was within 1-3 mV of E(m) at equilibrium. These measurements of a(i) (Cl) were obtained from the potential difference between the chloride-sensitive electrode and an intracellular indifferent micro-electrode filled with potassium chloride. If a potassium sulphate-filled indifferent micro-electrode was used, then values of a(i) (Cl) below about 5 mM were erroneously high, probably due to interference from other sarcoplasmic ions at the indifferent electrode.4. In solutions containing 15 mM bicarbonate and gassed with 5% CO(2), pH(i) was 6.9, corresponding to an internal bicarbonate concentration of 7.6 mM. E(Cl) measured in this solution was some 4 mV positive to E(m). Most of the difference between E(Cl) and E(m) could be ascribed to interference by sarcoplasmic bicarbonate on the basis of selectivity measurements of chloride against bicarbonate made on the ion-exchange resin in the relevant range of a(Cl).5. If bicarbonate/CO(2) in the external solution was replaced by HEPES/pure O(2) at constant pH, then pH(i) rose from 6.88 +/- 0.02 (mean +/- S.E.) to 7.05 +/- 0.02. A change in external pH of 1 unit caused pH(i) to change by about 0.02 unit and the intracellular buffering power was calculated to be about 35.6. In solution made hypertonic by the addition of sucrose, E(m) changed little or depolarized and E(Cl) and E(m) remained close. In contrast, in solution made hypertonic by the addition of solid sodium chloride (high-chloride solution) E(Cl) became negative to E(m). Conversely in low chloride solution E(Cl) became positive to E(m).7. When the chloride permeability (P(Cl)) was reduced by the use of acid solution, E(Cl) moved positive to E(m) indicating an accumulation of internal chloride. When P(Cl) was increased again by returning to more alkaline solution, E(m) depolarized to E(Cl).8. The results are consistent with the existence of a small, active movement of chloride, the effects of which are normally obscured by large passive movements of chloride when P(Cl) is large.
Similar articles
-
Non-passive chloride distribution in mammalian heart muscle: micro-electrode measurement of the intracellular chloride activity.J Physiol. 1979 Oct;295:83-109. doi: 10.1113/jphysiol.1979.sp012956. J Physiol. 1979. PMID: 521996 Free PMC article.
-
Regulation of chloride in quiescent sheep-heart Purkinje fibres studied using intracellular chloride and pH-sensitive micro-electrodes.J Physiol. 1979 Oct;295:111-37. doi: 10.1113/jphysiol.1979.sp012957. J Physiol. 1979. PMID: 42779 Free PMC article.
-
Measurement of intracellular chloride in guinea-pig vas deferens by ion analysis, 36chloride efflux and micro-electrodes.J Physiol. 1982 May;326:139-54. doi: 10.1113/jphysiol.1982.sp014182. J Physiol. 1982. PMID: 7108787 Free PMC article.
-
Intracellular pH: measurement, control, and metabolic interrelationships.CRC Crit Rev Clin Lab Sci. 1975 Sep;6(2):101-43. doi: 10.3109/10408367509151567. CRC Crit Rev Clin Lab Sci. 1975. PMID: 241590 Review.
-
The need for protein containing quality control materials for blood pH and electrolyte analyzers.Scand J Clin Lab Invest Suppl. 1996;224:179-86. doi: 10.3109/00365519609088638. Scand J Clin Lab Invest Suppl. 1996. PMID: 8865434 Review.
Cited by
-
Effect of denervation on a steady electric current generated at the end-plate region of rat skeletal muscle.J Physiol. 1986 Apr;373:97-114. doi: 10.1113/jphysiol.1986.sp016037. J Physiol. 1986. PMID: 3746683 Free PMC article.
-
Effects of fatigue and reduced intracellular pH on segment dynamics in 'isometric' relaxation of frog muscle fibres.J Physiol. 1989 Jun;413:159-74. doi: 10.1113/jphysiol.1989.sp017647. J Physiol. 1989. PMID: 2600846 Free PMC article.
-
Role of physiological ClC-1 Cl- ion channel regulation for the excitability and function of working skeletal muscle.J Gen Physiol. 2016 Apr;147(4):291-308. doi: 10.1085/jgp.201611582. J Gen Physiol. 2016. PMID: 27022190 Free PMC article. Review.
-
Non-passive chloride distribution in mammalian heart muscle: micro-electrode measurement of the intracellular chloride activity.J Physiol. 1979 Oct;295:83-109. doi: 10.1113/jphysiol.1979.sp012956. J Physiol. 1979. PMID: 521996 Free PMC article.
-
A highly-selective chloride microelectrode based on a mercuracarborand anion carrier.Sci Rep. 2019 Dec 11;9(1):18860. doi: 10.1038/s41598-019-54885-6. Sci Rep. 2019. PMID: 31827130 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources