Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Aug;29(8):995-1002.
doi: 10.1007/s10096-010-0958-3. Epub 2010 May 29.

Evaluation of the Xpert MRSA assay for rapid detection of methicillin-resistant Staphylococcus aureus from nares swabs of geriatric hospitalized patients and failure to detect a specific SCCmec type IV variant

Affiliations
Comparative Study

Evaluation of the Xpert MRSA assay for rapid detection of methicillin-resistant Staphylococcus aureus from nares swabs of geriatric hospitalized patients and failure to detect a specific SCCmec type IV variant

C Laurent et al. Eur J Clin Microbiol Infect Dis. 2010 Aug.

Abstract

Rapid and reliable detection of methicillin-resistant Staphylococcus aureus (MRSA) carriers is crucial for control of MRSA nosocomial transmission. We aimed to evaluate the performance of the GeneXpert real-time PCR system using the Xpert MRSA assay on a collection of 40 representative Belgian MRSA strains and for MRSA screening of geriatric inpatients. Double nasal swabs were used: the first swab for the Xpert MRSA assay and the second for culture onto chromogenic selective medium and enrichment broth. All but 1 of the 40 collection strains were recognized as MRSA by the Xpert MRSA assay. Nares swabs were prospectively collected from 246 inpatients including 25 nasal MRSA carriers. Compared with enriched cultures, the sensitivity, the specificity, and the positive and negative predictive values of the Xpert MRSA assay were 69.2%, 97.7%, 78.3%, and 96.3% respectively. The 7 evaluable false-negative results according to the assay were due to its possible lack of sensitivity (n = 3) and to the occurrence of a Belgian MRSA clone carrying a particular staphylococcal chromosomal cassette mec (SCCmec) type IV variant (n = 4) not targeted by the current Xpert MRSA assay. Because of the evolution of SCCmec in MRSA, new primers should be designed and further studies are warranted to ensure continuous monitoring of this assay.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Age Ageing. 2005 Sep;34(5):456-62 - PubMed
    1. J Clin Microbiol. 2008 Oct;46(10):3285-90 - PubMed
    1. Ann Clin Lab Sci. 2008 Summer;38(3):254-7 - PubMed
    1. J Antimicrob Chemother. 2009 Dec;64(6):1299-306 - PubMed
    1. J Clin Microbiol. 2009 May;47(5):1524-7 - PubMed

MeSH terms

LinkOut - more resources