[Comparison of the automatic sphygmo-oscillographic and auscultation methods of blood pressure measurements]
- PMID: 2051710
[Comparison of the automatic sphygmo-oscillographic and auscultation methods of blood pressure measurements]
Abstract
Sphygmomanometer S is the microcomputer device measuring blood pressure for (BP) on the basis of amplitude height and morphology of pulse waves, registered by the pulse converter placed in the air system of a cuff. The letter S stands the sphygmo-oscillographic method used in BP measurement (11). Sphygmomanometer S may be used to determine BP in infants, babies, children and adults (9, 10, 11, 12). The BP measurement results obtained in this way approximate the results of a direct method (1, 3, 8, 14). In order to carry out the simultaneous BP measurement by the sphygmo-oscillographic and the ascultatory methods, sphygmomanometer S was connected trough a manufactured Y-shaped joint with the aneroid-sphygmomanometer manufactured by INCO. This type of connection enabled the measurement to be realized with one cuff and both sphygmomanometers coincidentally. The measurement results of the systolic, diastolic and mean pressures, determined by the sphygmo-oscillographic method, were read from the sphygmomanometer S digital display. At the same time, the Korotkov tones were listened to through the stethscope placed over the brachial artery. The first phase of Korotkov tones was considered to be the systolic pressure while the fourth phase was the diastolic one. The mean pressure is determined by the sphygmomanometer S on the basis of the pulse wave peak amplitudes. In other words, pressure in the cuff, corresponding to the peak pulse waves, is the mean. However, in the ausculatory method, the mean pressure was calculated from the formula; Pm = Pd + 0,4 (Ps-Pd) where 'Pm is the mean pressure, Pd--the diastolic pressure and Ps the systolic pressure.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
[Measurement of arterial blood pressure using the sphygmomanometer-S and the direct method].Kardiol Pol. 1991;35(9):174-6. Kardiol Pol. 1991. PMID: 1753563 Polish.
-
[Comparison between brachial blood pressures obtained by aneroid sphygmomanometer and central aortic pressures: factors affecting the measurements].Turk Kardiyol Dern Ars. 2008 Jun;36(4):239-46. Turk Kardiyol Dern Ars. 2008. PMID: 18765967 Turkish.
-
Random zero sphygmomanometer versus automatic oscillometric blood pressure monitor; is either the instrument of choice?J Hum Hypertens. 1995 Nov;9(11):885-9. J Hum Hypertens. 1995. PMID: 8583467 Clinical Trial.
-
Arterial blood pressure measurement and pulse wave analysis--their role in enhancing cardiovascular assessment.Physiol Meas. 2010 Jan;31(1):R1-47. doi: 10.1088/0967-3334/31/1/R01. Epub 2009 Nov 26. Physiol Meas. 2010. PMID: 19940350 Review.
-
Measuring arterial blood pressure in humans: Auscultatory and automatic measurement techniques for human biological field studies.Am J Hum Biol. 2018 Jan;30(1). doi: 10.1002/ajhb.23063. Epub 2017 Sep 22. Am J Hum Biol. 2018. PMID: 28940503 Review.