Transcatheter closure of a patent ductus arteriosus in a preterm infant with an Amplatzer Vascular Plug IV device
- PMID: 20517997
- DOI: 10.1002/ccd.22657
Transcatheter closure of a patent ductus arteriosus in a preterm infant with an Amplatzer Vascular Plug IV device
Abstract
Rapid advances in paediatric interventional cardiology allow transcatheter closure of patent ductus arteriosus (PDA) in increasingly smaller patients. We describe a successful transcatheter closure of a large tubular PDA in a symptomatic preterm infant of 2,210 g using an Amplatzer Vascular Plug IV device.
Copyright © 2010 Wiley-Liss, Inc.
Similar articles
-
Transradial approach for percutaneous closure of patent ductus arteriosus with the Amplatzer duct occluder II: a case report.Catheter Cardiovasc Interv. 2011 Jan 1;77(1):103-7. doi: 10.1002/ccd.22636. Epub 2010 Oct 5. Catheter Cardiovasc Interv. 2011. PMID: 20925092
-
Extended applications of the Amplatzer vascular plug IV in infants.Cardiol Young. 2011 Apr;21(2):178-81. doi: 10.1017/S104795111000171X. Epub 2010 Dec 8. Cardiol Young. 2011. PMID: 21138616
-
Transcatheter closure of hemodynamic significant patent ductus arteriosus in 32 premature infants by amplatzer ductal occluder additional size-ADOIIAS.Catheter Cardiovasc Interv. 2017 Oct 1;90(4):612-617. doi: 10.1002/ccd.27091. Epub 2017 May 4. Catheter Cardiovasc Interv. 2017. PMID: 28471089
-
Transcatheter closure of patent ductus arteriosus: past, present and future.Arch Cardiovasc Dis. 2014 Feb;107(2):122-32. doi: 10.1016/j.acvd.2014.01.008. Epub 2014 Feb 20. Arch Cardiovasc Dis. 2014. PMID: 24560920 Review.
-
[Transcatheter occlusion of patent ductus arteriosus in a preterm infant and review of literatures].Zhonghua Er Ke Za Zhi. 2016 Jan;54(1):43-6. doi: 10.3760/cma.j.issn.0578-1310.2016.01.010. Zhonghua Er Ke Za Zhi. 2016. PMID: 26791923 Review. Chinese.
Cited by
-
Device Closure of Hemodynamically Significant Patent Ductus Arteriosus in Premature Infants.JACC Adv. 2024 Aug 24;3(10):101211. doi: 10.1016/j.jacadv.2024.101211. eCollection 2024 Oct. JACC Adv. 2024. PMID: 39263415 Free PMC article. Review.
-
A fully biodegradable patent ductus arteriosus occlude.J Mater Sci Mater Med. 2015 Feb;26(2):93. doi: 10.1007/s10856-015-5422-6. Epub 2015 Feb 4. J Mater Sci Mater Med. 2015. PMID: 25649512
-
Transcatheter closure of small ductus arteriosus with amplatzer vascular plug.Korean J Pediatr. 2013 Sep;56(9):396-400. doi: 10.3345/kjp.2013.56.9.396. Epub 2013 Sep 30. Korean J Pediatr. 2013. PMID: 24223601 Free PMC article.
-
Transcatheter Closure of Patent Ductus Arteriosus in Infants With Weight Under 1,500 Grams.Front Pediatr. 2020 Sep 22;8:558256. doi: 10.3389/fped.2020.558256. eCollection 2020. Front Pediatr. 2020. PMID: 33072674 Free PMC article. Review.
-
Transcatheter closure of tubular PDA with amplatzer plug 4 in preterm infants weighing between 900 and 3,400 g: the pros and cons.Front Cardiovasc Med. 2023 Oct 13;10:1283992. doi: 10.3389/fcvm.2023.1283992. eCollection 2023. Front Cardiovasc Med. 2023. PMID: 37900563 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical