. 2011 Jul;35(7):957-63.
doi: 10.1007/s00264-010-1059-8. Epub 2010 Jun 4.

Ten-year results with the Morscher press-fit cup: an uncemented, non-modular, porous-coated cup inserted without screws

Affiliations
Clinical Trial

Ten-year results with the Morscher press-fit cup: an uncemented, non-modular, porous-coated cup inserted without screws

Guido Garavaglia et al. Int Orthop. 2011 Jul.

Abstract

Total hip arthroplasty (THA) with well designed cementless acetabular implants has shown excellent results. The purpose of this study was to assess our clinical and radiological outcomes using an uncemented cup. We conducted a prospective cohort study including all consecutive primary THAs performed with the Morscher press-fit cup, an uncemented non-modular acetabular component, between March 1996 and December 1998. Patients were evaluated at ten years with clinical and radiological follow-up, patient satisfaction and questionnaire assessment using the Harris hip score (HHS), Merle d'Aubigné and Postel score, the UCLA score, the 12-item short-form health survey (SF-12) and a visual analog scale. Five hundred sixty-one THAs were performed in 518 patients. At 120 months (± 7.3 months), 303 patients with 335 THAs were still available for follow-up. None of the patients had required cup revision for aseptic loosening. At ten years, the cup survivorship was 98.8% (95% CI 97.4-99.5) with cup revision for any cause as an endpoint. No radiolucencies were seen around the cups, but osteolytic defects involved 21 stems (8.3%). Mean total linear polyethylene wear was 0.9 mm. The Morscher acetabular replacement cup provides excellent results at ten years. There were no revisions for aseptic loosening of the cup, and no osteolytic defects were found around the cup. Patient satisfaction was high and the clinical results were very good.

PubMed Disclaimer

Figures

Fig. 1
Fig. 1
The Morscher press-fit cup (Zimmer Ltd., Winterthur, Switzerland)
Fig. 2
Fig. 2
Patient flowchart

Similar articles

Cited by

References

    1. Latimer HA, Lachiewicz PF. Porous-coated acetabular components with screw fixation. Five to ten-year results. J Bone Joint Surg Am. 1996;78(7):975–981. - PubMed
    1. Smith SE, Harris WH. Total hip arthroplasty performed with insertion of the femoral component with cement and the acetabular component without cement. Ten to thirteen-year results. J Bone Joint Surg Am. 1997;79(12):1827–1833. - PubMed
    1. Barrack RL, Mulroy RD, Jr, Harris WH. Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review. J Bone Joint Surg Br. 1992;74:385–389. - PubMed
    1. Sullivan PM, MacKenzie JR, Callaghan JJ, Johnston RC. Total hip arthroplasty with cement in patients who are less than fifty years old. A sixteen to twenty-two-year follow-up study. J Bone Joint Surg Am. 1994;76:863–869. - PubMed
    1. Schulte KR, Callaghan JJ, Kelley SS, Johnston RC. The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-up. The results of one surgeon. J Bone Joint Surg Am. 1993;75:961–975. - PubMed

Publication types

MeSH terms