Comparison of nonspecific radioimmunoassay, high-performance liquid chromatography, and fluorescence polarization immunoassay for cyclosporine monitoring in renal transplantation
- PMID: 2053123
- DOI: 10.1097/00007691-199103000-00011
Comparison of nonspecific radioimmunoassay, high-performance liquid chromatography, and fluorescence polarization immunoassay for cyclosporine monitoring in renal transplantation
Abstract
Three methods, i.e., nonspecific radioimmunoassay (RIA; Incstar), fluorescence polarization immunoassay (FPIA; TDx Abbott), and high-performance liquid chromatography (HPLC), have been used for monitoring cyclosporine blood levels in renal transplantation patients. The levels obtained from 135 samples showed a modest correlation between RIA and HPLC, FPIA and HPLC, RIA and FRIA. The mean ratios of RIA to HPLC, FPIA to HPLC, and RIA to FPIA were 2.96, 4.14, and 0.73. The significant variations in cyclosporine levels result from the cross-reaction of antibody with some cyclosporine metabolites, by which these two methods often overestimate the true blood cyclosporine level. HPLC is a more effective and reliable method for pharmacokinetic studies and blood level monitoring of cyclosporine in clinical practice.
Similar articles
-
Comparison of Abbott TDx fluorescence polarization immunoassay, Sandoz radioimmunoassay, and high-performance liquid chromatography methods for the assay of serum cyclosporine.Transplant Proc. 1988 Apr;20(2 Suppl 2):345-7. Transplant Proc. 1988. PMID: 3284078
-
Measurement of cyclosporine by liquid chromatography and three immunoassays in blood from liver, cardiac, and renal transplant recipients.Clin Chem. 1992 Nov;38(11):2300-6. Clin Chem. 1992. PMID: 1424128
-
Analytical evaluation of TDx cyclosporine and metabolites fluorescence polarization immunoassay and comparison with the Cyclo-Trac RIA kit.J Clin Pharm Ther. 1990 Feb;15(1):45-51. doi: 10.1111/j.1365-2710.1990.tb00355.x. J Clin Pharm Ther. 1990. PMID: 2180968
-
Cyclosporine: a review of drug monitoring problems and presentation of a simple, accurate liquid chromatographic procedure that solves these problems.Clin Biochem. 1986 Apr;19(2):83-9. doi: 10.1016/s0009-9120(86)80053-4. Clin Biochem. 1986. PMID: 3518993 Review.
-
Cyclosporine pharmacokinetics and blood level monitoring.Drug Intell Clin Pharm. 1985 Feb;19(2):101-5. doi: 10.1177/106002808501900203. Drug Intell Clin Pharm. 1985. PMID: 3882375 Review.
Cited by
-
A review of assay methods for cyclosporin. Clinical implications.Clin Pharmacokinet. 1992 Sep;23(3):173-90. doi: 10.2165/00003088-199223030-00002. Clin Pharmacokinet. 1992. PMID: 1511535 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical