Gauging the likelihood of cavitation from short-pulse, low-duty cycle diagnostic ultrasound
- PMID: 2053214
- DOI: 10.1016/0301-5629(91)90125-g
Gauging the likelihood of cavitation from short-pulse, low-duty cycle diagnostic ultrasound
Abstract
Although no deleterious effects form diagnostic ultrasound have been reported in epidemiologic studies and surveys of widespread clinical usage (Ziskin and Petitti 1988), the conditions for the onset of transient cavitation must be investigated in the total evaluation of potential risks associated with diagnostic ultrasound applications. An extension of the results from the approximate theory developed by Holland and Apfel (1989) is applied in this paper to a population of nuclei to predict the onset of cavitation in host fluids with physical properties similar to those of biological fluids. From this analysis and from results of recent in vitro cavitation experiments, an index is developed which can gauge the likelihood of substantial microbubble growth in the presence of short-pulse, low-duty cycle diagnostic ultrasound.
Similar articles
-
Thresholds for transient cavitation produced by pulsed ultrasound in a controlled nuclei environment.J Acoust Soc Am. 1990 Nov;88(5):2059-69. doi: 10.1121/1.400102. J Acoust Soc Am. 1990. PMID: 2269722
-
Acoustic cavitation and the safety of diagnostic ultrasound.Ultrasound Med Biol. 1987 Oct;13(10):597-606. doi: 10.1016/0301-5629(87)90057-3. Ultrasound Med Biol. 1987. PMID: 3318067 Review.
-
Exploiting flow to control the in vitro spatiotemporal distribution of microbubble-seeded acoustic cavitation activity in ultrasound therapy.Phys Med Biol. 2014 Nov 21;59(22):6941-57. doi: 10.1088/0031-9155/59/22/6941. Epub 2014 Oct 28. Phys Med Biol. 2014. PMID: 25350470
-
Sonochemiluminescence observation and acoustic detection of cavitation induced by pulsed HIFU at a tissue-fluid interface.Ultrason Sonochem. 2013 Nov;20(6):1370-5. doi: 10.1016/j.ultsonch.2013.03.002. Epub 2013 Mar 26. Ultrason Sonochem. 2013. PMID: 23628637
-
Acoustic cavitation produced by microsecond pulses of ultrasound: a discussion of some selected results.J Acoust Soc Am. 1992 Feb;91(2):1113-9. doi: 10.1121/1.402638. J Acoust Soc Am. 1992. PMID: 1556312 Review.
Cited by
-
Analyzing the Impact of Increasing Mechanical Index and Energy Deposition on Shear Wave Speed Reconstruction in Human Liver.Ultrasound Med Biol. 2015 Jul;41(7):1948-57. doi: 10.1016/j.ultrasmedbio.2015.02.019. Epub 2015 Apr 18. Ultrasound Med Biol. 2015. PMID: 25896024 Free PMC article.
-
Contrast-enhanced ultrasound imaging and in vivo circulatory kinetics with low-boiling-point nanoscale phase-change perfluorocarbon agents.Ultrasound Med Biol. 2015 Mar;41(3):814-31. doi: 10.1016/j.ultrasmedbio.2014.10.020. Epub 2015 Jan 22. Ultrasound Med Biol. 2015. PMID: 25619781 Free PMC article.
-
Analytical Simulation of the Microbubble Collapsing in a Welding Fusion Pool.Materials (Basel). 2023 Jan 1;16(1):410. doi: 10.3390/ma16010410. Materials (Basel). 2023. PMID: 36614749 Free PMC article.
-
Release of doxorubicin from unstabilized and stabilized micelles under the action of ultrasound.J Nanosci Nanotechnol. 2007 Mar;7(3):1028-33. doi: 10.1166/jnn.2007.218. J Nanosci Nanotechnol. 2007. PMID: 17450870 Free PMC article.
-
Further investigation of the mechanism of Doxorubicin release from P105 micelles using kinetic models.Colloids Surf B Biointerfaces. 2007 Mar 15;55(1):59-66. doi: 10.1016/j.colsurfb.2006.11.006. Epub 2006 Nov 16. Colloids Surf B Biointerfaces. 2007. PMID: 17207611 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Other Literature Sources