Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience
- PMID: 20532783
- DOI: 10.1007/s00330-010-1822-7
Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience
Abstract
Objective: To explore the clinical value of low-dose prospective ECG-triggering dual-source CT (DSCT) angiography in infants and children with complex congenital heart disease (CHD) compared with transthoracic echocardiography (TTE).
Methods: Thirty-five patients (mean age: 16 months, range: 2 months to 6 years; male 15; mean weight: 12 kg) underwent low-dose prospective ECG-triggering DSCT angiography and TTE. Surgeries were performed in 29 patients, and conventional cardiac angiography (CCA) was performed in 8 patients. The accuracy was calculated based on the surgical and/or CCA findings. The overall imaging quality was evaluated on a five-point scale.
Results: A total of 146 separate cardiovascular deformities were confirmed. DSCT missed three atrial septal defects and a patent ductus arteriosus. The accuracy of DSCT angiography and TTE was 97.3% (142/146) and 92.5% (135/146), respectively. Overall test parameters for DSCT angiography and TTE were similar (sensitivity, 97.3% vs 92.5%; specificity, 99.8% vs 99.8%). The average subjective image quality score was 4.3 ± 0.7. The mean effective dose was 0.38 ± 0.09 mSv.
Conclusions: Prospective ECG-triggering DSCT angiography with a very low effective radiation dose allows the accurate diagnosis of anomalies in infants and children with complex CHD compared with TTE. It has great promise to become a commonly used second-line technique for complex CHD.
Similar articles
-
[Application of prospective ECG-triggering dual-source CT angiography in infants and children with congenital heart disease].Zhonghua Yi Xue Za Zhi. 2012 Jan 17;92(3):179-83. Zhonghua Yi Xue Za Zhi. 2012. PMID: 22490740 Chinese.
-
Application of prospective ECG-gated high-pitch 128-slice dual-source CT angiography in the diagnosis of congenital extracardiac vascular anomalies in infants and children.PLoS One. 2014 Dec 29;9(12):e115793. doi: 10.1371/journal.pone.0115793. eCollection 2014. PLoS One. 2014. PMID: 25546178 Free PMC article.
-
Accuracy, image quality, and radiation dose of prospectively ECG-triggered high-pitch dual-source CT angiography in infants and children with complex coarctation of the aorta.Acad Radiol. 2014 Oct;21(10):1248-54. doi: 10.1016/j.acra.2014.04.019. Epub 2014 Aug 2. Acad Radiol. 2014. PMID: 25097011 Clinical Trial.
-
Diagnostic accuracy of sub-mSv prospective ECG-triggering cardiac CT in young infant with complex congenital heart disease.Int J Cardiovasc Imaging. 2016 Jun;32(6):991-8. doi: 10.1007/s10554-016-0854-8. Epub 2016 Feb 20. Int J Cardiovasc Imaging. 2016. PMID: 26897005
-
The value of low-dose prospective ECG-gated dual-source CT angiography in the diagnosis of coarctation of the aorta in infants and children.Clin Radiol. 2012 Aug;67(8):738-45. doi: 10.1016/j.crad.2011.12.007. Epub 2012 Feb 14. Clin Radiol. 2012. PMID: 22336668
Cited by
-
Role of Computed Tomography in Pre- and Postoperative Evaluation of a Double-Outlet Right Ventricle.J Cardiovasc Imaging. 2021 Jul;29(3):205-227. doi: 10.4250/jcvi.2020.0196. Epub 2021 Mar 8. J Cardiovasc Imaging. 2021. PMID: 34080329 Free PMC article. Review.
-
Radiation dose of cardiac computed tomography - what has been achieved and what needs to be done.Eur Radiol. 2011 Mar;21(3):505-9. doi: 10.1007/s00330-010-1984-3. Epub 2010 Oct 19. Eur Radiol. 2011. PMID: 20957482 Review.
-
Radiation dose management for pediatric cardiac computed tomography: a report from the Image Gently 'Have-A-Heart' campaign.Pediatr Radiol. 2018 Jan;48(1):5-20. doi: 10.1007/s00247-017-3991-x. Epub 2018 Jan 1. Pediatr Radiol. 2018. PMID: 29292481 Free PMC article. Review.
-
Third-generation dual-source 70-kVp chest CT angiography with advanced iterative reconstruction in young children: image quality and radiation dose reduction.Pediatr Radiol. 2016 Apr;46(4):462-72. doi: 10.1007/s00247-015-3510-x. Epub 2016 Jan 6. Pediatr Radiol. 2016. PMID: 26739141
-
Evaluation of complex congenital heart disease in infants using low dose cardiac computed tomography.Int J Cardiovasc Imaging. 2021 Apr;37(4):1455-1460. doi: 10.1007/s10554-020-02118-7. Epub 2021 Jan 3. Int J Cardiovasc Imaging. 2021. PMID: 33392877