Preparation and physical properties of a novel biocompatible porcine corneal acellularized matrix
- PMID: 20532994
- DOI: 10.1007/s11626-010-9328-9
Preparation and physical properties of a novel biocompatible porcine corneal acellularized matrix
Abstract
This study was to investigate the stability, physico-mechanical property and biocompatibility of porcine corneal acellularized matrix (PCAM) that was prepared using human sera treatment to decellularize corneas. The stability (the rate of biodegradation) and physico-mechanical property (water uptake, density, and porosity) of PCAM were not compromised, compared with porcine fresh cornea matrix (PFCM, p > 0.05). The contact and extract cytotoxicity tests with human corneal epithelial cells and human keratocytes showed that PCAM has a good biocompatibility ex vivo and no cytotoxic effect. These results present the ability to create safety scaffolds that function as cornea grafts and provide a novel experimental approach for the study of cornea tissue engineering using acellular porcine cornea.
Similar articles
-
Reconstruction of a tissue-engineered cornea with porcine corneal acellular matrix as the scaffold.Cells Tissues Organs. 2010;191(3):193-202. doi: 10.1159/000235680. Epub 2009 Aug 19. Cells Tissues Organs. 2010. PMID: 19690400
-
Development of a rabbit corneal equivalent using an acellular corneal matrix of a porcine substrate.Mol Vis. 2008;14:2180-9. Epub 2008 Nov 30. Mol Vis. 2008. PMID: 19052652 Free PMC article.
-
In vivo evaluation of a novel scaffold for artificial corneas prepared by using ultrahigh hydrostatic pressure to decellularize porcine corneas.Mol Vis. 2009 Oct 13;15:2022-8. Mol Vis. 2009. PMID: 19844587 Free PMC article.
-
[Transplantation of corneal endothelial cells].Nippon Ganka Gakkai Zasshi. 2002 Dec;106(12):805-35; discussion 836. Nippon Ganka Gakkai Zasshi. 2002. PMID: 12610838 Review. Japanese.
-
Strategies for developing decellularized corneal scaffolds.Exp Eye Res. 2013 Mar;108:42-7. doi: 10.1016/j.exer.2012.12.012. Epub 2012 Dec 31. Exp Eye Res. 2013. PMID: 23287438 Review.
Cited by
-
Keeping an eye on decellularized corneas: a review of methods, characterization and applications.J Funct Biomater. 2013 Jul 10;4(3):114-61. doi: 10.3390/jfb4030114. J Funct Biomater. 2013. PMID: 24956084 Free PMC article.
-
Targeted transplantation of human umbilical cord blood endothelial progenitor cells with immunomagnetic nanoparticles to repair corneal endothelium defect.Stem Cells Dev. 2015 Mar 15;24(6):756-67. doi: 10.1089/scd.2014.0255. Epub 2014 Dec 17. Stem Cells Dev. 2015. PMID: 25315152 Free PMC article.
-
Evaluation of novel decellularizing corneal stroma for cornea tissue engineering applications.Int J Ophthalmol. 2012;5(4):415-8. doi: 10.3980/j.issn.2222-3959.2012.04.02. Epub 2012 Aug 18. Int J Ophthalmol. 2012. PMID: 22937497 Free PMC article.
-
Efficacy of the nucleotide-binding oligomerzation domain 1 inhibitor Nodinhibit-1 on corneal alkali burns in rats.Int J Ophthalmol. 2015 Oct 18;8(5):860-5. doi: 10.3980/j.issn.2222-3959.2015.05.02. eCollection 2015. Int J Ophthalmol. 2015. PMID: 26558192 Free PMC article.
-
Air pollutant particulate matter 2.5 induces dry eye syndrome in mice.Sci Rep. 2018 Dec 13;8(1):17828. doi: 10.1038/s41598-018-36181-x. Sci Rep. 2018. PMID: 30546125 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources