Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 May-Jun;35(3):353-61.
doi: 10.2341/09-234-L.

Parameters influencing increase in pulp chamber temperature with light-curing devices: curing lights and pulpal flow rates

Affiliations

Parameters influencing increase in pulp chamber temperature with light-curing devices: curing lights and pulpal flow rates

Sung-Ho Park et al. Oper Dent. 2010 May-Jun.

Erratum in

  • Oper Dent. 2010 Jul-Aug;35(4):487

Abstract

This laboratory study examined the effects of curing lights with different light intensities and changing flow rate on the increase in pulpal temperature during the light curing process and the rate of the subsequent decrease in temperature after the termination of light curing. The tip of a temperature sensor was positioned on the pulpal dentinal wall of the buccal side of the maxillary premolar. Metal tubes were inserted in the palatal and buccal root of the tooth, one for water inflow and the other for water outflow. The tubes were connected to a pump to control the flow rate. The water flow rate was set to 4.2 microl/minute, 28 microl/minute or 70 microl/minute. At each flow rate, the unprepared tooth was light cured from the buccal side 1 mm from the buccalsurface, using four different curing lights. The temperature data were recorded and stored on a computer every second for three minutes. The curing lights that were used were: Astralis 10 (QTH(high), Ivoclar Vivadent), Bluephase 16i (LED(conv), Ivoclar Vivadent) and two experimental LED-curing lights (LED(exp2000), LED(exp3000), Ivoclar Vivadent). The power densities were 1200 mW/cm2, 1600 mW/cm2, 2000 mW/cm2 and 3000 mW/cm2, respectively. The curing lights, LED(conv), LED(exp2000) and LED(exp3000) were activated for 60 seconds, and the QTH(high) was activated for 30 sec- onds. The maximum intrapulpal temperature (TM) and rate of temperature change at 30 seconds after turning off the light (S(30LO)) were analyzed by two-way ANOVA with a post-hoc Tukey test (p < 0.05). The influencing factors were the flow rates and curing lights.

Results: The T(MAX) ranged from 41.0 degrees C to 53.5 degrees C. There was a difference between the curing lights (p < 0.05), with LED(exp3000) > LED(exp2000) > LED(conv) > QTH(high). There was no difference in T(MAX) between the different flow rates (p > 0.05). Both the curing lights and flow rates affected the SE(30LO) (p < 0.05). The S(30LO) was LED(exp3000) < LED(exp2000) > LEDon, , QTH(high) (p < 0.05). The S(30LO) at 70 microl/minutes was higher than at 4.2 pd/minutes and 28 microl/minutes (p < 0.05).

Clinical implication: Because the increase in temperature is directly related to the light intensity and exposure time, curing devices with high power density (> 1200 mW/cm2) should only be activated for a short period of time (< 15 seconds) even in teeth without cavity preparation. The flow rate had only a negligible effect on the temperature increase.

PubMed Disclaimer

Similar articles

Cited by

Publication types

Substances

LinkOut - more resources