Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Sep;3(5):595-603.
doi: 10.1161/CIRCIMAGING.109.920538. Epub 2010 Jun 9.

Iodine-123 metaiodobenzylguanidine imaging and carbon-11 hydroxyephedrine positron emission tomography compared in patients with left ventricular dysfunction

Affiliations
Comparative Study

Iodine-123 metaiodobenzylguanidine imaging and carbon-11 hydroxyephedrine positron emission tomography compared in patients with left ventricular dysfunction

Ichiro Matsunari et al. Circ Cardiovasc Imaging. 2010 Sep.

Abstract

Background: Although both (123)I-metaiodobenzylguanidine ((123)I-MIBG) imaging and (11)C-hydroxyephedrine ((11)C-HED) positron emission tomography (PET) are used for assessing cardiac sympathetic innervation, their relationship remains unknown. The aims were to determine whether (123)I-MIBG parameters such as heart-to-mediastinum ratio (H/M) are associated with quantitative measures by (11)C-HED PET and to compare image quality, defect size, and location between (123)I-MIBG single-photon emission computed tomography (SPECT) and (11)C-HED PET.

Methods and results: Twenty-one patients (mean left ventricular ejection fraction, 39 ± 15%) underwent (123)I-MIBG imaging and (11)C-HED PET. Early (15-minute), late (3-hour) H/M, and washout rate (WR) were calculated for (123)I-MIBG. Myocardial retention and WR was calculated for (11)C-HED. Using a polar map approach, defect was defined as the area with relative activity <60% of the maximum. Both the early (r=0.76) and late (r=0.84) (123)I-MIBG H/M were correlated with (11)C-HED retention. (123)I-MIBG WR was correlated with (11)C-HED WR (r=0.57). Defect size could not be measured in 3 patients because of poor quality (123)I-MIBG SPECT, whereas (11)C-HED defect was measurable in all patients. Although defect size measured by early or late (123)I-MIBG SPECT was closely correlated with that by (11)C-HED PET (early: r=0.94; late: r=0.88), the late (123)I-MIBG overestimated defect size particularly in the inferior and septal regions.

Conclusions: (123)I-MIBG H/M gives a reliable estimate of cardiac sympathetic innervation as measured by (11)C-HED PET. Furthermore, despite the close correlation in defect size, (11)C-HED PET appears to be more suitable for assessing regional abnormalities than does (123)I-MIBG SPECT.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources