Human cardiovascular effects of a new generation conducted electrical weapon
- PMID: 20537475
- DOI: 10.1016/j.forsciint.2010.05.003
Human cardiovascular effects of a new generation conducted electrical weapon
Abstract
Objectives: The conducted electrical weapon (CEW) is used by law enforcement to control potentially violent people. Much of the research in CEW safety has focused on the TASER X26, which uses a single deployment cartridge. New Generation CEW (NGCEW) technology has been developed that uses a different circuit and multiple cartridges that can be simultaneously deployed. The objective of this study is to examine the cardiovascular effects of the NGCEW in different deployment possibilities.
Methods: This was a prospective study of human subjects during NGCEW training courses. Subjects received a NGCEW probe deployment to the frontal torso in 1 of 3 configurations: 2, 3,or 4 embedded probes and then underwent a 10-s exposure. Before and after vital signs, electrocardiograms (ECGs), and serum troponin I values were obtained. Real-time echocardiography was utilized before, during and after the exposure to evaluate heart rate and rhythm.
Results: Initially, a 1st version NGCEW (NGCEWv1) that was in the final stages of manufacturer verification was used at the training courses. It had not been publicly released. During a NGCEWv1 exposure with 2 probes, there was an apparent brief episode of cardiac capture. Testing was halted and the manufacturer was notified. The device was redesigned and the study continued when a redesigned, 2nd version (NGCEWv2) was used. The NGCEW1 was studied in 8 subjects. The NGCEWv2 was studied in 45 subjects with no evidence of cardiac capture. There were no important post-exposure vital sign, troponin I or ECG changes found in any volunteers.
Conclusions: An apparent brief myocardial capture event occurred with the NGCEWv1. This device was not released and was redesigned. The NGCEWv2 appears to exhibit a reasonable degree of cardiac safety with frontal torso exposures and multiple probe combination configurations.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Similar articles
-
Human Health Risks of Conducted Electrical Weapon Exposure: A Systematic Review.JAMA Netw Open. 2021 Feb 1;4(2):e2037209. doi: 10.1001/jamanetworkopen.2020.37209. JAMA Netw Open. 2021. PMID: 33576818 Free PMC article.
-
Physiologic effects of a new-generation conducted electrical weapon on human volunteers.J Emerg Med. 2014 Mar;46(3):428-35. doi: 10.1016/j.jemermed.2013.08.069. Epub 2013 Nov 12. J Emerg Med. 2014. PMID: 24238599
-
Immediate cardiovascular effects of the Taser X26 conducted electrical weapon.Emerg Med J. 2009 Aug;26(8):567-70. doi: 10.1136/emj.2008.063560. Emerg Med J. 2009. PMID: 19625551
-
Cardiovascular and physiologic effects of conducted electrical weapon discharge in resting adults.Acad Emerg Med. 2006 Jun;13(6):589-95. doi: 10.1197/j.aem.2006.01.017. Epub 2006 Mar 21. Acad Emerg Med. 2006. PMID: 16551780 Clinical Trial.
-
Exposures to conducted electrical weapons (including TASER® devices): how many and for how long are acceptable?J Forensic Sci. 2015 Jan;60 Suppl 1:S116-29. doi: 10.1111/1556-4029.12672. Epub 2014 Nov 28. J Forensic Sci. 2015. PMID: 25443856 Review.
Cited by
-
An evaluation of two conducted electrical weapons and two probe designs using a swine comparative cardiac safety model.Forensic Sci Med Pathol. 2013 Sep;9(3):333-42. doi: 10.1007/s12024-013-9422-x. Epub 2013 Mar 30. Forensic Sci Med Pathol. 2013. PMID: 23543462
-
Electromuscular incapacitating devices discharge and risk of severe bradycardia.Am J Forensic Med Pathol. 2015 Jun;36(2):94-8. doi: 10.1097/PAF.0000000000000143. Am J Forensic Med Pathol. 2015. PMID: 25710795 Free PMC article.
-
Blood lactate concentration after exposure to conducted energy weapons (including TASER® devices): is it clinically relevant?Forensic Sci Med Pathol. 2013 Sep;9(3):386-94. doi: 10.1007/s12024-013-9436-4. Epub 2013 Apr 19. Forensic Sci Med Pathol. 2013. PMID: 23605975 Review.
-
A comparative brief on conducted electrical weapon safety.Wien Med Wochenschr. 2019 May;169(7-8):185-192. doi: 10.1007/s10354-018-0616-4. Epub 2018 Feb 1. Wien Med Wochenschr. 2019. PMID: 29392503 Review. English.
-