Evaluation of a new automated panel of assays for the detection of anti-PF4/heparin antibodies in patients suspected of having heparin-induced thrombocytopenia
- PMID: 20539902
- DOI: 10.1160/TH10-01-0002
Evaluation of a new automated panel of assays for the detection of anti-PF4/heparin antibodies in patients suspected of having heparin-induced thrombocytopenia
Abstract
Heparin-induced thrombocytopenia (HIT) is a life-threatening complication of heparin treatment; the prognosis depends on early and accurate diagnosis, and prompt start of alternative anticoagulants. Because of high sensitivity, the commercially available immunologic assays are widely used, though not suited to be run on single samples and with a turnaround time of 2-3 hours. We evaluated two new, rapid, automated, semi-quantitative chemiluminescent immunoassays in HIT suspected patients: HemosIL AcuStar HIT-IgG(PF4-H) (specific for IgG anti-PF4/heparin antibodies) and HemosIL AcuStar HIT-Ab(PF4-H) (detecting IgG, IgM and IgA anti-PF4/heparin antibodies) (both from Instrumentation Laboratory). A total of 102 patients with suspected HIT were included; HIT was diagnosed in 17 (16.7%). No false negative cases were observed using either the HemosIL AcuStar HIT-IgG(PF4-H) or the HIT-Ab(PF4-H) assay (sensitivity and negative predictive values = 100%; negative likelihood ratios <0.01). The specificity was higher for the HemosIL AcuStar HIT-IgG(PF4-H) in comparison with that of the HemosIL AcuStar HIT-Ab(PF4-H) (96.5% vs. 81.2%). Higher values of the HemosIL AcuStar HIT-IgG(PF4-H) were associated with increased probability of HIT. Patients with confirmed HIT and thrombotic complications had significantly higher levels of HemosIL AcuStar HIT-IgG(PF4-H) than those without thrombotic complications. The HemosIL AcuStar HIT-IgG(PF4-H) and HIT-Ab(PF4-H) assays showed a very high sensitivity, and therefore they can reliably be used to rule out HIT in suspected patients. The diagnostic specificity was greatly increased by using the HemosIL AcuStar HIT-IgG(PF4-H). Both the assays are reproducible (CVs <6%), rapid (turnaround time 30 minutes), automated, and semi-quantitative, and they can be run for single sample testing.
Similar articles
-
Evaluation of automated immunoassays in the diagnosis of heparin induced thrombocytopenia.Thromb Res. 2013 Mar;131(3):e85-90. doi: 10.1016/j.thromres.2013.01.005. Epub 2013 Jan 23. Thromb Res. 2013. PMID: 23351665
-
Evaluation of two new automated chemiluminescent assays (HemosIL® AcuStar HIT-IgG and HemosIL® AcuStar HIT-Ab) for the detection of heparin-induced antibodies in the diagnosis of heparin-induced thrombocytopenia.Int J Lab Hematol. 2012 Aug;34(4):410-6. doi: 10.1111/j.1751-553X.2012.01413.x. Epub 2012 Mar 8. Int J Lab Hematol. 2012. PMID: 22405611
-
[New stream for the measurement of anti-platelet factor 4/heparin antibodies].Rinsho Byori. 2013 Feb;61(2):137-43. Rinsho Byori. 2013. PMID: 23672091 Japanese.
-
Profile of Instrumentation Laboratory's HemosIL® AcuStar HIT-Ab(PF4-H) assay for diagnosis of heparin-induced thrombocytopenia.Expert Rev Mol Diagn. 2017 May;17(5):419-426. doi: 10.1080/14737159.2017.1304213. Epub 2017 Mar 16. Expert Rev Mol Diagn. 2017. PMID: 28271738 Review.
-
Testing for heparin-induced thrombocytopenia antibodies.Transfus Med Rev. 2006 Oct;20(4):259-72. doi: 10.1016/j.tmrv.2006.05.001. Transfus Med Rev. 2006. PMID: 17008164 Review.
Cited by
-
Rapid immunoassays for diagnosis of heparin-induced thrombocytopenia: Comparison of diagnostic accuracy, reproducibility, and costs in clinical practice.PLoS One. 2017 Jun 8;12(6):e0178289. doi: 10.1371/journal.pone.0178289. eCollection 2017. PLoS One. 2017. PMID: 28594835 Free PMC article.
-
Acute non-heparin-induced thrombocytopenia during hemodiafiltration in a patient with multiple myeloma.Clin Case Rep. 2019 Feb 22;7(4):699-702. doi: 10.1002/ccr3.1997. eCollection 2019 Apr. Clin Case Rep. 2019. PMID: 30997067 Free PMC article.
-
Massive Left Atrial Thrombus in Two Patients with Heparin-Induced Thrombocytopenia Type II after Cardiac Surgery.TH Open. 2018 Sep 26;2(3):e334-e337. doi: 10.1055/s-0038-1672188. eCollection 2018 Jul. TH Open. 2018. PMID: 31249958 Free PMC article.
-
Functional Assays in the Diagnosis of Heparin-Induced Thrombocytopenia: A Review.Molecules. 2017 Apr 11;22(4):617. doi: 10.3390/molecules22040617. Molecules. 2017. PMID: 28398258 Free PMC article. Review.
-
Heparin-induced thrombocytopenia with very high antibody titer is associated with slower platelet recovery and higher risk of thrombosis.Int J Hematol. 2024 Sep;120(3):290-296. doi: 10.1007/s12185-024-03811-2. Epub 2024 Jul 8. Int J Hematol. 2024. PMID: 38976179
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous