Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Nov;97(2):165-71.
doi: 10.1016/j.radonc.2010.04.024. Epub 2010 Jun 10.

A systematic review on the role of FDG-PET/CT in tumour delineation and radiotherapy planning in patients with esophageal cancer

Affiliations

A systematic review on the role of FDG-PET/CT in tumour delineation and radiotherapy planning in patients with esophageal cancer

Christina T Muijs et al. Radiother Oncol. 2010 Nov.

Abstract

Purpose: FDG-PET/CT has proven to be useful in the staging process of esophageal tumours. This review analysed the role of FDG-PET/CT in tumour delineation and radiotherapy planning in comparison with CT alone among patients with esophageal cancer. Thereby we focused on the detection of the primary tumour and lymph nodes by FDG-PET/CT, changes in target volume (TV) delineation based on FDG-PET/CT and its validity, changes in inter- and intra-observer variability in TV delineation, consequences for radiotherapy treatment planning with regard to either target volumes or organs at risk and finally on the validation of FDG-PET/CT-based TVs in terms of treatment outcome.

Methods: A literature search was performed in MEDLINE and Cochrane library databases for studies concerning the current value of FDG-PET/CT in tumour detection and delineation and radiotherapy-planning procedures among patients with esophageal cancer. Both prospective and retrospective studies were included.

Results: Fifty publications met the eligibility criteria, of which 19 were review papers and one was a case report. The remaining 30 publications reported on the results of original studies. FDG-PET was able to identify most primary tumours, with a sensitivity and specificity for the detection of metastatic lymph nodes of 30-93% and 79-100%. The use of FDG-PET/CT resulted in changes of target volumes, and consequently in changes in treatment planning. However, evidence supporting the validity of the use of FDG-PET/CT in the tumour delineation process is very limited. Only three studies reported a significant positive correlation between FDG-PET-based tumour lengths and pathological findings. There were two studies that tested the influence of FDG-PET/CT to the inter- and intra-observer variability. One of them found a significant decrease in inter- and intra-observer variability, while the others did not. Furthermore, there are no studies demonstrating the use of PET/CT in terms of improved locoregional control or survival.

Conclusion: Since the literature is very limited standard implementation of FDG-PET/CT into the tumour delineation process for radiation treatment seems unjustified and needs further clinical validation first.

PubMed Disclaimer

Publication types

MeSH terms

Substances