Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Sep;182(9):764-72.
doi: 10.1055/s-0029-1245440. Epub 2010 Jun 11.

Imaging of brain metastases of bronchial carcinomas with 7 T MRI - initial results

Affiliations

Imaging of brain metastases of bronchial carcinomas with 7 T MRI - initial results

C Mönninghoff et al. Rofo. 2010 Sep.

Abstract

Purpose: To compare the depiction of brain metastases of bronchial carcinomas on susceptibility-weighted and contrast-enhanced images with 7 T and at 1.5 T MRI.

Materials and methods: Twelve patients with brain metastases of bronchial carcinomas underwent 7 T and 1.5 T MRI. Minimum intensity projections (MinIP) of a 1.5 T SWI sequence (voxel size = 0.9 x 0.9 x 2.0 mm(3)) were compared to 7 T SWI MinIPs (voxel size = 0.4 x 0.4 x 1.5 mm(3)). A T 1-w 3D MPRAGE at 1.5 T (voxel size = 1 x 1 x 1 mm(3) after double-dose (DD) gadoterate meglumine, Gd-DOTA) was compared to a 7 T MPRAGE sequence (voxel size = 0.7 x 0.7 x x 0.7 mm(3), single dose (SD) Gd-DOTA) in all patients, and to DD Gd-DOTA in 6 patients after a 10 minute delay. The number of intracranial microhemorrhages in SWI MinIPs and the number of contrast-enhancing metastases in MPRAGE images were compared in each patient grouped into three size ranges (< or = 2 mm, > 2 mm and < 6 mm, > or = 6 mm) by two radiologists in consensus.

Results: In all 12 patients the 7 T SWI with spatially higher resolution allowed the identification of 87 versus 67 cerebral microhemorrhages at 1.5 T. 7 T T 1-w images after SD Gd-DOTA depicted 198 brain metastases versus 238 at 1.5 T after DD Gd-DOTA. After doubling the contrast dose in six patients, 4 additional brain metastases were identified at 7 T.

Conclusion: Our preliminary results indicate that despite the higher spatial resolution the detection of brain metastases on 7 T MPRAGE images is almost equal to 1.5 T MPRAGE images. The 7 T SWI sequence with spatially higher resolution allowed the detection of 20 % more microhemorrhages in brain metastases compared to the 1.5 T SWI sequence.

PubMed Disclaimer

MeSH terms

Substances

LinkOut - more resources