Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2010 Aug;19(6):449-57.
doi: 10.1111/j.1532-849X.2010.00615.x. Epub 2010 Jun 8.

Relevant anatomic and biomechanical studies for implant possibilities on the atrophic maxilla: critical appraisal and literature review

Affiliations
Review

Relevant anatomic and biomechanical studies for implant possibilities on the atrophic maxilla: critical appraisal and literature review

Paulo Henrique Orlato Rossetti et al. J Prosthodont. 2010 Aug.

Abstract

Purpose: The purpose of this review was to highlight anatomic and biomechanical aspects of atrophic maxillae for implant possibilities.

Materials and methods: A MEDLINE electronic search of the years 1966 to 2009 was conducted with the keywords "atrophic,""resorbed,""edentulous," and "maxilla."

Results: Twenty papers presented the following findings: (1) previous use of a removable prosthesis is a risk factor for resorption, with flabby tissues related to the severity of resorption; (2) implants in the reconstructed maxilla (< or =5 mm) and supporting overdentures had a higher risk for bone loss based on the worse periimplant soft-tissue health observed; (3) bleeding on probing was found with pocket depths > or =5 mm in half of the zygomatic implants; (4) prevalence of bone septa is higher in atrophic maxillae, and changes on nasopalatine canal can reduce up to 44.4% of the full length of buccal bone plates; (5) female patients have less medullar bone quantity and connectivity than male patients; (6) transectioning of nutrient vessels is easier and accelerates resorption; (7) stress does not concentrate on maxillary sinus base cortical bone contiguous to trabecular bone; (8) splinted implants receive nine times less load than nonsplinted implants even under oblique loading; (9) implant stability quotient (ISQ) values for implants ranged between 60 and 65; (10) in vivo force transfer to implants is similar between fixed prostheses and overdentures; (11) inclined implants generate better biomechanical responses; (12) masticatory efficiency and bite forces improve in maxillectomized patients who receive obturators with milled bar attachments.

Conclusion: Sound implant-supported choices for an atrophic maxilla must be made with a thorough understanding of its anatomic and biomechanical factors.

PubMed Disclaimer

Substances

LinkOut - more resources