Electrophysiologic study: its predictive value for ventricular arrhythmias

Affiliations

Electrophysiologic study: its predictive value for ventricular arrhythmias

Daniel R Gold et al. Tex Heart Inst J. 2010.

Abstract

Studies have shown the predictive value of inducible ventricular tachycardia and clinical arrhythmia in patients who have structural heart disease. We examined the possible predictive value of electrophysiologic study before the placement of an implantable cardioverter-defibrillator. Our retrospective study group comprised 315 patients who had ventricular tachycardia that was inducible during electrophysiologic study and who had undergone at least 1 month of follow-up (247 men; mean age, 66.9 +/- 13.5 yr; mean follow-up, 24.9 +/- 14.8 mo). Recorded characteristics included induced ventricular tachycardia cycle length, atrio-His and His-ventricular electrograms, PR and QT intervals, QRS duration, and drug therapy. Of the 315 patients, 97 experienced ventricular arrhythmia during the follow-up period, as registered by 184 of more than 400 interrogations. There were 187 episodes of ventricular arrhythmia (tachycardia, 178; fibrillation, 9) during 652.5 person-years of follow-up. Subjects with a cycle length > or =240 msec were more likely to have an earlier 1st arrhythmia than those with a cycle length <240 msec (P=0.032). A quarter of the subjects with a cycle length > or =240 msec had their 1st arrhythmia by 19.14 months, compared with 23.8 months for a quarter of the subjects with a cycle length <240 msec (P <0.032). Among the electrophysiologic characteristics examined, inducible ventricular tachycardia with a cycle length > or =240 msec is predictive of appropriate implantable cardioverter-defibrillator therapy at an earlier time. This may have prognostic implications that warrant implantable cardioverter-defibrillator programming to enable appropriate antitachycardia pacing in this group of patients.

Keywords: Arrhythmias, cardiac/prevention & control; death, sudden, cardiac/prevention & control; defibrillators, implantable; electric countershock; electric stimulation; electrophysiologic techniques, cardiac; predictive value of tests; resuscitation; tachycardia, ventricular/therapy; ventricular fibrillation/therapy.

PubMed Disclaimer

Figures

None
Fig. 1 Months to 1st ventricular arrhythmia.

Similar articles

References

    1. Gregoratos G, Abrams J, Epstein AE, Freedman RA, Hayes DL, Hlatky MA, et al. ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices–summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines). J Am Coll Cardiol 2002;40(9):1703–19. - PubMed
    1. Buxton AE, Lee KL, Fisher JD, Josephson ME, Prystowsky EN, Hafley G. A randomized study of the prevention of sudden death in patients with coronary artery disease. Multicenter Unsustained Tachycardia Trial Investigators [published erratum appears in N Engl J Med 2000;342(17):1300]. N Engl J Med 1999;341(25):1882–90. - PubMed
    1. Catanzaro JN, Makaryus AN, Sison C, Vavasis C, Donaldson D, Beldner S, et al. Clinical predictors of appropriate implantable-cardioverter defibrillator discharge [published erratum appears in Pacing Clin Electrophysiol 2007;30(11):1427]. Pacing Clin Electrophysiol 2007;30 Suppl 1:S120-4. - PubMed
    1. Moss AJ, Hall WJ, Cannom DS, Daubert JP, Higgins SL, Klein H, et al. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators. N Engl J Med 1996;335(26):1933–40. - PubMed
    1. Daubert JP, Zareba W, Hall WJ, Schuger C, Corsello A, Leon AR, et al. Predictive value of ventricular arrhythmia inducibility for subsequent ventricular tachycardia or ventricular fibrillation in Multicenter Automatic Defibrillator Implantation Trial (MADIT) II patients. J Am Coll Cardiol 2006;47(1): 98–107. - PubMed

MeSH terms