Automatic best reference slice selection for smooth volume reconstruction of a mouse brain from histological images
- PMID: 20550984
- DOI: 10.1109/TMI.2010.2050594
Automatic best reference slice selection for smooth volume reconstruction of a mouse brain from histological images
Abstract
In this paper, we present a novel and effective method for registering histological slices of a mouse brain to reconstruct a 3-D volume. First, intensity variations in images are corrected through an intensity standardization process so that intensity values remain constant across slices. Second, the image space is transformed to a feature space where continuous variables are taken as high fidelity image features for accurate registration. Third, in order to improve the quality of the reconstructed volume, an automatic best reference slice selection algorithm is developed based on iterative assessment of image entropy and mean square error of the registration process. Fourth, a novel metric for evaluating the quality of the reconstructed volume is developed. Finally, the effect of optimal reference slice selection on the quality of registration and subsequent reconstruction is demonstrated.
Similar articles
-
3D volume reconstruction of a mouse brain from histological sections using warp filtering.J Neurosci Methods. 2006 Sep 30;156(1-2):84-100. doi: 10.1016/j.jneumeth.2006.02.020. Epub 2006 Apr 3. J Neurosci Methods. 2006. PMID: 16580732
-
Smoothness-guided 3-D reconstruction of 2-D histological images.Neuroimage. 2011 May 1;56(1):197-211. doi: 10.1016/j.neuroimage.2011.01.060. Epub 2011 Jan 28. Neuroimage. 2011. PMID: 21277374
-
Iterative Principal Axes Registration method for analysis of MR-PET brain images.IEEE Trans Biomed Eng. 1995 Nov;42(11):1079-87. doi: 10.1109/10.469374. IEEE Trans Biomed Eng. 1995. PMID: 7498911
-
A piecewise monotone subgradient algorithm for accurate L¹-TV based registration of physical slices with discontinuities in microscopy.IEEE Trans Med Imaging. 2013 May;32(5):901-18. doi: 10.1109/TMI.2013.2242896. Epub 2013 Jan 25. IEEE Trans Med Imaging. 2013. PMID: 23362248 Review.
-
Slice-to-volume medical image registration: A survey.Med Image Anal. 2017 Jul;39:101-123. doi: 10.1016/j.media.2017.04.010. Epub 2017 Apr 28. Med Image Anal. 2017. PMID: 28482198 Review.
Cited by
-
3D volume reconstruction from serial breast specimen radiographs for mapping between histology and 3D whole specimen imaging.Med Phys. 2017 Mar;44(3):935-948. doi: 10.1002/mp.12077. Med Phys. 2017. PMID: 28064435 Free PMC article.
-
Hemodynamic Influence on Smooth Muscle Cell Kinetics and Phenotype During Early Vein Graft Adaptation.Ann Biomed Eng. 2017 Mar;45(3):644-655. doi: 10.1007/s10439-016-1725-0. Epub 2016 Sep 13. Ann Biomed Eng. 2017. PMID: 27624660 Free PMC article.
-
Optimized SIFTFlow for registration of whole-mount histology to reference optical images.J Med Imaging (Bellingham). 2016 Oct;3(4):047501. doi: 10.1117/1.JMI.3.4.047501. Epub 2016 Oct 19. J Med Imaging (Bellingham). 2016. PMID: 27774494 Free PMC article.
-
Joint segmentation of anatomical and functional images: applications in quantification of lesions from PET, PET-CT, MRI-PET, and MRI-PET-CT images.Med Image Anal. 2013 Dec;17(8):929-45. doi: 10.1016/j.media.2013.05.004. Epub 2013 May 23. Med Image Anal. 2013. PMID: 23837967 Free PMC article.
-
Mapping Histological Slice Sequences to the Allen Mouse Brain Atlas Without 3D Reconstruction.Front Neuroinform. 2018 Dec 11;12:93. doi: 10.3389/fninf.2018.00093. eCollection 2018. Front Neuroinform. 2018. PMID: 30618698 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical