Deep sclerectomy with the Ex-PRESS X-200 implant for the surgical treatment of glaucoma
- PMID: 20552258
- DOI: 10.1007/s10792-010-9382-z
Deep sclerectomy with the Ex-PRESS X-200 implant for the surgical treatment of glaucoma
Abstract
The efficacy and safety of a newly designed Ex-PRESS X-200 drainage device for the surgical treatment of glaucoma was evaluated. A clinical, prospective, monocentric, non-randomised, unmasked study on patients with medically uncontrolled glaucoma was performed. A superficial scleral flap was created. A posterior deep sclerectomy (DS) was dissected without opening the Schlemm's canal and an Ex-PRESS X-200 device was inserted under the scleral flap into the anterior chamber to drain aqueous humour into the intrascleral space. Biomicroscopy, best-corrected visual acuity (BCVA), applanation intra-ocular pressure (IOP) measurements, and fundus examination were performed before surgery, on the first day, the first week, and 1, 2, 3, 6, 12 and 18 months after surgery. The mean follow-up was 18.6 ± 2.4 months (mean ± SD) for the 26 eyes that were treated with the Ex-PRESS X-200 device. Pre-operatively, the mean BCVA was 0.6 ± 0.3, the mean IOP was 22.0 ± 5.1 mmHg, and the mean number of medications per patients was 2.8 ± 0.8. Eighteen months after surgery the mean BCVA was 0.5 ± 0.4, the mean IOP was reduced to 12.0 ± 3.9 mmHg, and the mean number of medications per patient was 0.6 ± 1.2. Eighty-five percent of patients achieved an IOP < 18 mmHg with or without medication and 69% without medication. Post-operative complications were hyphaema (15%), Seidel (15%), encysted blebs (54%) and bleb fibrosis in 8% of patients. Mitomycin C(MMC) was administered to 15 patients (58%) with needling being performed on 10 (38%) of these patients. Mid-term results of DS with the Ex-PRESS X-200 implant demonstrated its efficacy in controlling IOP with few post-operative complications in difficult eyes with an increased risk of surgery failure.
Similar articles
-
Combined Ex-PRESS LR-50/IOL implantation in modified deep sclerectomy plus phacoemulsification for glaucoma associated with cataract.Eur J Ophthalmol. 2011 Jan-Feb;21(1):12-9. doi: 10.5301/ejo.2010.541. Eur J Ophthalmol. 2011. PMID: 20623471
-
Deep sclerectomy with mitomycin C in failed trabeculectomy.Eye (Lond). 2007 Jan;21(1):23-8. doi: 10.1038/sj.eye.6702183. Epub 2005 Nov 25. Eye (Lond). 2007. PMID: 16311522
-
Phacoemulsification-deep sclerectomy modified by trabeculum microperforations and implantation of lens anterior capsule as autologous scleral implant.Curr Med Res Opin. 2010 Aug;26(8):2025-32. doi: 10.1185/03007995.2010.500857. Curr Med Res Opin. 2010. PMID: 20590394 Clinical Trial.
-
Effect of different application depths of mitomycin-C in deep sclerectomy with collagen implant: a randomized controlled trial.Clin Exp Ophthalmol. 2009 Apr;37(3):286-92. doi: 10.1111/j.1442-9071.2009.02030.x. Clin Exp Ophthalmol. 2009. PMID: 19472537 Clinical Trial.
-
Deep sclerectomy.Dev Ophthalmol. 2012;50:29-36. doi: 10.1159/000334772. Epub 2012 Apr 17. Dev Ophthalmol. 2012. PMID: 22517171 Review.
Cited by
-
ExPress mini shunt device with trabeculectomy surgery in patients with uncontrolled glaucoma of Middle Eastern descent.Saudi J Ophthalmol. 2021 Feb 27;34(3):177-181. doi: 10.4103/1319-4534.310416. eCollection 2020 Jul-Sep. Saudi J Ophthalmol. 2021. PMID: 34085009 Free PMC article.
-
Effect of glaucoma implant surgery on intraocular pressure reduction, flare count, anterior chamber depth, and corneal endothelium in primary open-angle glaucoma.Jpn J Ophthalmol. 2017 Jul;61(4):334-346. doi: 10.1007/s10384-017-0512-2. Epub 2017 Apr 3. Jpn J Ophthalmol. 2017. PMID: 28374269
-
Long-term outcomes and risk factors for failure with the EX-press glaucoma drainage device.Eye (Lond). 2014 Jan;28(1):1-8. doi: 10.1038/eye.2013.234. Epub 2013 Nov 15. Eye (Lond). 2014. PMID: 24232313 Free PMC article. Review.
-
Modified deep sclerectomy combined with Ex-PRESS filtration device versus trabeculectomy for primary open angle glaucoma.Int J Ophthalmol. 2017 May 18;10(5):728-732. doi: 10.18240/ijo.2017.05.11. eCollection 2017. Int J Ophthalmol. 2017. PMID: 28546928 Free PMC article.
-
Surgical treatment of neovascular glaucoma with Ex-PRESS glaucoma shunt: Case report.Medicine (Baltimore). 2017 Sep;96(35):e7845. doi: 10.1097/MD.0000000000007845. Medicine (Baltimore). 2017. PMID: 28858093 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical