Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Oct;27(9):1107-12.
doi: 10.1111/j.1540-8175.2010.01209.x.

Diagnosis of congenital unicuspid aortic valve in adult population: the value and limitation of transesophageal echocardiography

Affiliations

Diagnosis of congenital unicuspid aortic valve in adult population: the value and limitation of transesophageal echocardiography

John W Chu et al. Echocardiography. 2010 Oct.

Abstract

Background: This study aimed to assess the accuracy of two-dimensional echocardiography (echo) in diagnosing unicuspid aortic valve (UAV) and to determine echo features that could improve the diagnosis.

Method: We reviewed transthoracic/transesophageal echoes (TTE/TEE) from our hospital database for adult patients who had aortic valve surgery with a preoperative echo diagnosis of UAV or equivocal diagnosis of bicuspid aortic valve (BAV) BAV/UAV. Morphological characteristics of AV and ascending aortic dimensions were evaluated.

Results: Nineteen patients were identified, 13 (11 Male, 2 Female, mean age 47 ± 10 years) had surgically confirmed diagnosis of UAV, six had BAV. The incidence of UAV was 2.6%. For diagnosing UAV, the sensitivity and specificity of TTE was 27% and 50% and those of TEE was 75% and 86%, respectively. For TTE, positive predictive value (PPV) was 60% and negative predictive value (NPV) was 20%. By TEE, PPV was 90% and the NPV was 67%. In UAV patients, 85% had severe aortic stenosis (mean gradient 45 ± 16 mmHg, AVA: 0.9 ± 0.2 cm²). 46% had ascending aorta aneurysm (mean aortic root, sinutubular junction, ascending aorta dimensions: 36 ± 3 mm, 31 ± 4 mm and 41 ± 8 mm). Patients with ascending aortic aneurysm were younger (41 ± 11 years vs. 52 ± 5 years, P < 0.05) All UAV were unicommissural with a posteriorly positioned commissural attachment, 69% were heavily calcified. Diagnostic accuracy was limited by quality of images, severity, and distribution of calcification.

Conclusion: TEE is the diagnostic modality of choice in UAV. Identifying several echo features may improve its diagnostic accuracy.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources