Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2011 Mar;17(3):351-5.
doi: 10.1016/j.bbmt.2010.05.013. Epub 2010 May 27.

The effect of different harvest strategies on the nucleated cell yields of bone marrow collection

Affiliations
Free article
Comparative Study

The effect of different harvest strategies on the nucleated cell yields of bone marrow collection

Tso-Fu Wang et al. Biol Blood Marrow Transplant. 2011 Mar.
Free article

Abstract

To improve bone marrow (BM) harvest of the volunteer donors in our institute, we changed from the single-hole needle to the multi-side-hole needle after March 2002, and examined the midway total nucleated cell (TNC) counts during collection after September 2004. The aims of this retrospective study were to evaluate BM harvest yields obtained through different strategies and to examine the correlation between final and midway BM harvests. The distribution of BM harvesting by different strategies was 235 donors with single-hole needles (group A), 389 donors with 5-side-hole needles (group B), and 365 donors with 5-side-hole needles and midway TNC counts (group C). The nucleated cell density of the collected BM was significantly improved by modifying the harvest strategy (0.202 × 10(8)/mL in group A, 0.219 × 10(8)/mL in group B, and 0.250 × 10(8)/mL in group C; P < .001). The percentage of unacceptable TNC dose (<2 × 10(8)/kg) was also decreased in all 3 groups (to 5.9%, 3.6%, and 0%, respectively; P < .001). Multiple regression analysis revealed that donor weight, white blood cell count, and harvest strategy were positively correlated with BM TNC density (P < .001), whereas harvested BM volume was negatively correlated with TNC density (P < .001). On linear regression analysis, highly significant correlations were noted between midway and final TNC densities (r = 0.8774; P < .001) as well as between harvested BM volume and TNC count (r = 0.7937; P < .001). Changing the harvesting needle and checking the midway TNC count improved the harvest outcome.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms