Abstract
The histologic effects of a contact ultrasound applicator were compared with those of the immersion applicator that is currently used clinically for the treatment of glaucoma. The applicator coupling cone uses a distensible rubber membrane that can be inflated to control stand-off distance relative to the surface of the eye. This feature allows the focal point of the therapeutic beam to be placed at selective depths. Histologic comparisons of lesions in rabbit and pig eyes showed lesions in the sclera and ciliary body that were similar to those produced by the immersion transducer when the same focal position was used. Moving the focal point to a greater depth resulted in less superficial damage, yet still produced ciliodestruction. Damage to the blood supply of the ciliary body, as found in human cadaver eyes, may be an additional mechanism of action of therapeutic ultrasound, and perhaps of other transscleral high-energy modalities.
Similar articles
-
[Principles and histologic effects of the treatment of hypertension with focused high-intensity ultrasound].Ophtalmologie. 1990 Mar-Apr;4(2):135-7. Ophtalmologie. 1990. PMID: 2235001 Review. French.
-
Histologic effects of a new device for high-intensity focused ultrasound cyclocoagulation.Invest Ophthalmol Vis Sci. 2010 Oct;51(10):5092-8. doi: 10.1167/iovs.09-5135. Epub 2010 May 19. Invest Ophthalmol Vis Sci. 2010. PMID: 20484580
-
Energy levels needed for cyclophotocoagulation: a comparison of transscleral contact cw-YAG and krypton lasers in the rabbit eye.Ophthalmic Surg. 1993 Aug;24(8):530-3. Ophthalmic Surg. 1993. PMID: 8233316
-
Histologic changes in porcine eyes treated with high-intensity focused ultrasound.Ann Ophthalmol. 1987 Apr;19(4):133-8. Ann Ophthalmol. 1987. PMID: 3619262
-
[Treatment of refractory glaucoma with high density focused ultrasonics].J Fr Ophtalmol. 1995;18(1):3-12. J Fr Ophtalmol. 1995. PMID: 7738293 Review. French.
Cited by
-
Microwave cyclodestruction: evaluation on human eyes.Br J Ophthalmol. 1995 Jul;79(7):678-82. doi: 10.1136/bjo.79.7.678. Br J Ophthalmol. 1995. PMID: 7662635 Free PMC article. Clinical Trial.
-
Therapeutic ultrasound for glaucoma: clinical use of a low-frequency low-power ultrasound device for lowering intraocular pressure.J Ther Ultrasound. 2014 Sep 26;2:15. doi: 10.1186/2050-5736-2-15. eCollection 2014. J Ther Ultrasound. 2014. PMID: 25512870 Free PMC article.
-
Efficacy and safety of ultrasound cycloplasty for the treatment of glaucoma: a Meta-analysis.Int J Ophthalmol. 2023 Aug 18;16(8):1317-1325. doi: 10.18240/ijo.2023.08.19. eCollection 2023. Int J Ophthalmol. 2023. PMID: 37602344 Free PMC article.
-
High intensity focused ultrasound cyclocoagulation in dogs with primary glaucoma: a preliminary study.Open Vet J. 2018;8(3):305-312. doi: 10.4314/ovj.v8i3.9. Epub 2018 Aug 13. Open Vet J. 2018. PMID: 30148082 Free PMC article.
-
Focused ultrasound in ophthalmology.Clin Ophthalmol. 2016 Sep 27;10:1865-1875. doi: 10.2147/OPTH.S99535. eCollection 2016. Clin Ophthalmol. 2016. PMID: 27757007 Free PMC article. Review.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical