The use of iohexol in patients with previous reactions to ionic contrast material. A multicenter clinical trial
- PMID: 2055737
- DOI: 10.1097/00004424-199105000-00004
The use of iohexol in patients with previous reactions to ionic contrast material. A multicenter clinical trial
Abstract
Patients who have had prior reactions to iodinated contrast material have increased risk for repeat reactions. Nonionic contrast agents have been reported to reduce the risk of contrast reactions. A multicenter study was undertaken to determine the repeat reaction rate using iohexol. Two hundred ninety-one repeat reactors were included in the study, of whom one-third received premedication. Sixteen patients (5.5%) experienced repeat reactions; none was severe, and only one was more serious than the prior reaction. This is in contrast to the reported 16% to 44% repeated reaction rate for ionic agents. We conclude that iohexol is effective in reducing the occurrence of repeat reactions from the level observed with ionic agents without premedication. Iohexol appears to be as effective as ionic agents plus premedication in this high-risk group of patients.
Comment in
-
Adverse reactions to contrast media. Ionic and nonionic media and steroids.Invest Radiol. 1991 May;26(5):402-3. doi: 10.1097/00004424-199105000-00002. Invest Radiol. 1991. PMID: 1815541 No abstract available.
-
What we know and what we don't.Invest Radiol. 1991 May;26(5):401. doi: 10.1097/00004424-199105000-00001. Invest Radiol. 1991. PMID: 2055735 No abstract available.
Similar articles
-
Comparison of the rates of adverse drug reactions. Ionic contrast agents, ionic agents combined with steroids, and nonionic agents.Invest Radiol. 1991 May;26(5):404-10. doi: 10.1097/00004424-199105000-00003. Invest Radiol. 1991. PMID: 2055736 Clinical Trial.
-
[Severe reactions to iodinated contrast agents: is anaphylaxis responsible?].J Radiol. 2001 Sep;82(9 Pt 1):973-7. J Radiol. 2001. PMID: 11591924 French.
-
Protective effect against repeat adverse reactions to iodinated contrast medium: Premedication vs. changing the contrast medium.Eur Radiol. 2016 Jul;26(7):2148-54. doi: 10.1007/s00330-015-4028-1. Epub 2015 Oct 1. Eur Radiol. 2016. PMID: 26427700
-
Iodide mumps due to low-osmolality contrast material.AJR Am J Roentgenol. 1992 Nov;159(5):1099-100. doi: 10.2214/ajr.159.5.1414783. AJR Am J Roentgenol. 1992. PMID: 1414783 Review. No abstract available.
-
Reactions to radiocontrast media.Allergy Asthma Proc. 2002 Sep-Oct;23(5):347-51. Allergy Asthma Proc. 2002. PMID: 12476546 Review.
Cited by
-
Contrast media toxicity in children.Pediatr Radiol. 2008 May;38 Suppl 2:S281-4. doi: 10.1007/s00247-008-0773-5. Pediatr Radiol. 2008. PMID: 18401627 Review. No abstract available.
-
Adverse effects of contrast media: incidence, prevention and management.Drug Saf. 1998 Oct;19(4):313-24. doi: 10.2165/00002018-199819040-00006. Drug Saf. 1998. PMID: 9804445 Review.
-
Adverse reactions to intravenous iodinated contrast media: a primer for radiologists.Emerg Radiol. 2006 Jul;12(5):210-5. doi: 10.1007/s10140-006-0488-6. Epub 2006 May 11. Emerg Radiol. 2006. PMID: 16688432 Review.
-
Reactions to radiocontrast material. Anaphylactoid events in radiology.Clin Rev Allergy Immunol. 1999 Winter;17(4):469-96. doi: 10.1007/BF02737651. Clin Rev Allergy Immunol. 1999. PMID: 10829816 Review. No abstract available.