A parametric study of valve orientation on the flow patterns of the Penn State pulsatile pediatric ventricular assist device
- PMID: 20559131
- DOI: 10.1097/MAT.0b013e3181e3cb22
A parametric study of valve orientation on the flow patterns of the Penn State pulsatile pediatric ventricular assist device
Abstract
Because of the shortage of organs for transplant in pediatric patients with end-stage heart failure, Penn State is developing a pneumatically driven 12 cc pulsatile pediatric ventricular assist device (PVAD). A major concern is the flow field changes related to the volume decrease and its effect on device thrombogenicity. Previous studies of similar devices have shown that changes in the orientation of the inlet valve can lead to improvement in the flow field. Herein, the fluid dynamic effects of orientation changes at both the inlet and outlet valves are studied. Using two-dimensional particle image velocimetry, we examine the flow field in vitro using an acrylic model of the PVAD in a mock circulatory loop. Regardless of valve orientation, the overall flow pattern inside the PVAD remains similar, but important differences were seen locally in the wall shear rates, which is notable because shear rates >500 s may prevent thrombus formation. As the inlet valve was rotated toward the fluid side of the PVAD, we observed an increase in inlet jet velocity and wall shear rates along the inlet port wall. A corresponding rotation of the outlet valve increases the wall shear rate along the outer wall near the device outlet. Wall shear rates were all higher when both valves were rotated toward the fluid side of the device, with the best rates found at orientations of +15 degrees for both the inlet and outlet valves. Overall, orientations of +15 degrees or +30 degrees of both the inlet and outlet valve resulted in an increase in wall shear rates and could aid in the reduction of thrombus formation inside the PVAD.
Similar articles
-
The 12 cc Penn State pulsatile pediatric ventricular assist device: fluid dynamics associated with valve selection.J Biomech Eng. 2008 Aug;130(4):041019. doi: 10.1115/1.2939342. J Biomech Eng. 2008. PMID: 18601461
-
Flow behavior within the 12-cc Penn State pulsatile pediatric ventricular assist device: an experimental study of the initial design.Artif Organs. 2008 Jun;32(6):442-52. doi: 10.1111/j.1525-1594.2008.00565.x. Epub 2008 Apr 16. Artif Organs. 2008. PMID: 18422800
-
The 12 cc Penn State pulsatile pediatric ventricular assist device: flow field observations at a reduced beat rate with application to weaning.ASAIO J. 2008 May-Jun;54(3):325-31. doi: 10.1097/MAT.0b013e3181695cfe. ASAIO J. 2008. PMID: 18496284
-
Innovative developments of the heart valves designed for use in ventricular assist devices.Expert Rev Med Devices. 2005 Jan;2(1):61-71. doi: 10.1586/17434440.2.1.61. Expert Rev Med Devices. 2005. PMID: 16293030 Review.
-
Rotary pumps and diminished pulsatility: do we need a pulse?ASAIO J. 2013 Jul-Aug;59(4):355-66. doi: 10.1097/MAT.0b013e31829f9bb3. ASAIO J. 2013. PMID: 23820272 Review.
Cited by
-
Polymeric trileaflet prosthetic heart valves: evolution and path to clinical reality.Expert Rev Med Devices. 2012 Nov;9(6):577-94. doi: 10.1586/erd.12.51. Expert Rev Med Devices. 2012. PMID: 23249154 Free PMC article. Review.
-
Effect of Hematocrit and Elevated Beat Rate on the 12cc Penn State Pediatric Ventricular Assist Device.ASAIO J. 2023 Dec 1;69(12):1065-1073. doi: 10.1097/MAT.0000000000002028. Epub 2023 Aug 7. ASAIO J. 2023. PMID: 37549654 Free PMC article.
-
Extracorporeal membrane oxygenation versus counterpulsatile, pulsatile, and continuous left ventricular unloading for pediatric mechanical circulatory support.Pediatr Crit Care Med. 2013 Nov;14(9):e424-37. doi: 10.1097/PCC.0b013e3182a551b0. Pediatr Crit Care Med. 2013. PMID: 24108116 Free PMC article.
-
Flow visualization of a pediatric ventricular assist device during stroke volume reductions related to weaning.Ann Biomed Eng. 2011 Jul;39(7):2046-58. doi: 10.1007/s10439-011-0291-8. Epub 2011 Mar 15. Ann Biomed Eng. 2011. PMID: 21404124 Free PMC article.
-
Toward the Virtual Benchmarking of Pneumatic Ventricular Assist Devices: Application of a Novel Fluid-Structure Interaction-Based Strategy to the Penn State 12 cc Device.J Biomech Eng. 2017 Aug 1;139(8):0810081-08100810. doi: 10.1115/1.4036936. J Biomech Eng. 2017. PMID: 28586917 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Research Materials