Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Apr;175(1-4):475-85.
doi: 10.1007/s10661-010-1545-x. Epub 2010 Jun 19.

Contributions of dry and wet depositions of polychlorinated dibenzo-p-dioxins and dibenzofurans to a contaminated site resulting from a penetachlorophenol manufacturing process

Affiliations

Contributions of dry and wet depositions of polychlorinated dibenzo-p-dioxins and dibenzofurans to a contaminated site resulting from a penetachlorophenol manufacturing process

Hwang J Chang et al. Environ Monit Assess. 2011 Apr.

Abstract

The soils at a factory for manufacturing pentachlorophenol were heavily contaminated by polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). In order to verify the contributions of dry and wet deposition of PCDD/Fs from the ambient air, the concentration of PCDD/Fs in ambient air and soil were measured, the partition of particle- and gas-phases of atmospheric PCDD/Fs was calculated, and the annual fluxes of total dry and wet PCDD/F depositions were modeled. Average atmospheric PCDD/F concentration was 1.24 ng Nm(-3) (or 0.0397 ng I-TEQ Nm(-3)). Moreover, over 92.8% of total PCDD/Fs were in the particle phase, and the dominant species were high chlorinated congeners. The total PCDD/F fluxes of dry and wet deposition were 119.5 ng m(-2) year(-1) (1.34 ng I-TEQ m(-2) year(-1)) and 82.0 ng m(-2) year(-1) (1.07 ng I-TEQ m(-2) year(-1)), respectively. By scenario simulation, the total fluxes of dry and wet PCDD/F depositions were 87.1 and 68.6 ng I-TEQ, respectively. However, the estimated PCDD/F contents in the contaminated soil were 839.9 μ g I-TEQ. Hence, the contributions of total depositions of atmospheric PCDD/F were only 0.02%. The results indicated that the major sources of PCDD/F for the contaminated soil could be attributed to the pentachlorophenol manufacturing process.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Air Waste Manag Assoc. 2003 Sep;53(9):1149-57 - PubMed
    1. Chemosphere. 2002 Mar;46(9-10):1329-33 - PubMed
    1. Sci Total Environ. 1998 Aug 12;219(1):53-81 - PubMed
    1. Chemosphere. 2009 Mar;74(11):1463-70 - PubMed
    1. J Hazard Mater. 2008 Dec 15;160(1):220-7 - PubMed

MeSH terms

LinkOut - more resources