Monte Carlo simulations of laser Doppler blood flow measurements in tissue
- PMID: 20563178
- DOI: 10.1364/AO.29.002371
Monte Carlo simulations of laser Doppler blood flow measurements in tissue
Abstract
Light propagation in a model for blood perfusion in tissue was simulated with Monte Carlo calculations to investigate the dependence of the output of laser Doppler perfusion meters on the configuration of the optical probe and on the multiple scattering of photons by moving particles in the tissue. Laser Doppler perfusion meters registrating the first moment ?v? and the first weighted moment ?v?(s) of the spectral power density S(v) of intensity fluctuations on a detector viewing tissue illuminated by a laser are considered. The model was scaled up about a factor of 10 compared with real tissue, to make experimental tests possible. From the simulations of the Doppler scattering, it will be shown that the location of the effective probe volume of the perfusion meter can be extended to deeper layers in tissue by increasing the distance between the illuminating light beam and the detector. This opens the possibility to measure perfusion in skin layers as a function of the distance to the surface. Other calculations show how the degree of multiple scattering of individual photons by moving cells determines which flow parameter is measured with the perfusion meter. If the degree is low, the output of the meter depends linearly on the mean velocity of cells. For high degrees, a dependence on the root mean square value of this distribution is found. At a high moving particle concentration, multiple scattering by moving particles also results in deviations from the linear dependence of ?v? on the concentration of moving particles and in deviations from the concentration independence of ?v?(s). Intensity distributions of light inside the tissue model were obtained from the simulations.
Similar articles
-
Laser Doppler flowmetry: measurements in a layered perfusion model and Monte Carlo simulations of measurements.Appl Opt. 1991 Jun 20;30(18):2592-7. doi: 10.1364/AO.30.002592. Appl Opt. 1991. PMID: 20700248
-
Analytical calculations and Monte Carlo simulations of laser Doppler flowmetry using a cubic lattice model.Appl Opt. 1992 Jun 1;31(16):3061-7. doi: 10.1364/AO.31.003061. Appl Opt. 1992. PMID: 20725251
-
Evaluation of algorithms for microperfusion assessment by fast simulations of laser Doppler power spectral density.Phys Med Biol. 2011 Dec 21;56(24):7709-23. doi: 10.1088/0031-9155/56/24/002. Epub 2011 Nov 16. Phys Med Biol. 2011. PMID: 22085805
-
Measurement of particle flux in a static matrix with suppressed influence of optical properties, using low coherence interferometry.Opt Express. 2010 Feb 1;18(3):2849-57. doi: 10.1364/OE.18.002849. Opt Express. 2010. PMID: 20174114
-
[The status of laser Doppler examination in patients with arterial occlusive disease].Herz. 1988 Dec;13(6):382-91. Herz. 1988. PMID: 3061920 Review. German.
Cited by
-
Multichannel laser-Doppler probe for blood perfusion measurements with depth discrimination.Med Biol Eng Comput. 1998 Nov;36(6):740-7. doi: 10.1007/BF02518878. Med Biol Eng Comput. 1998. PMID: 10367466
-
Review of methodological developments in laser Doppler flowmetry.Lasers Med Sci. 2009 Mar;24(2):269-83. doi: 10.1007/s10103-007-0524-0. Epub 2008 Jan 31. Lasers Med Sci. 2009. PMID: 18236103 Review.
-
Laser speckle contrast imaging of the skin: interest in processing the perfusion data.Med Biol Eng Comput. 2012 Feb;50(2):103-5. doi: 10.1007/s11517-011-0856-6. Epub 2011 Dec 29. Med Biol Eng Comput. 2012. PMID: 22205575
LinkOut - more resources
Other Literature Sources