Measurement of an intact knee kinematics using gait and fluoroscopic analysis
- PMID: 20563558
- DOI: 10.1007/s00167-010-1190-5
Measurement of an intact knee kinematics using gait and fluoroscopic analysis
Abstract
A method has been introduced in this paper to measure the kinematics of a knee joint and to use it as a boundary condition to model the knee's mechanical behaviour. A mobile C-Arm fluoroscopy system (Ziehm Vision R) and a CCD camera were used for the measurement of a patient's knee kinematics. The fluoroscopic images were recorded with 12 fps and then sent to Matlab software (Mathworks, Natick, MA, USA) for image processing. In parallel, CT scan images of the knee bones were used to create the 3D anatomical geometry of the knee by aid of Mimics software (Materialise NV). However, the geometrical model of the two medial and lateral menisci was generated from MRI data. The 3D geometrical model of the knee was then sent to Abaqus finite element software (Simulia Dassault Systems) to analyse the knee joint contact loads by introducing the boundary condition which was obtained from fluoroscopic images. The finite element model was used to evaluate the stress distribution on the cartilages during the gait. The result was then compared with the experimental data of gait analysis. The comparison between the results showed a close agreement between the two outcomes.
Similar articles
-
The Effect of Knee Flexion on Length Changes and Stress Distribution of Ligaments: A Displacement Controlled Finite Element Analysis.Orthopedics. 2021 Jan 1;44(1):e61-e67. doi: 10.3928/01477447-20201028-01. Epub 2020 Nov 3. Orthopedics. 2021. PMID: 33141235
-
EMG-Assisted Muscle Force Driven Finite Element Model of the Knee Joint with Fibril-Reinforced Poroelastic Cartilages and Menisci.Sci Rep. 2020 Feb 20;10(1):3026. doi: 10.1038/s41598-020-59602-2. Sci Rep. 2020. PMID: 32080233 Free PMC article.
-
Inter-insertional distance is a poor correlate for ligament load: analysis from in vivo gait kinetics data.J Biomech. 2013 Sep 3;46(13):2264-70. doi: 10.1016/j.jbiomech.2013.06.023. Epub 2013 Jul 17. J Biomech. 2013. PMID: 23871234
-
A finite element model of the human knee joint for the study of tibio-femoral contact.J Biomech Eng. 2002 Jun;124(3):273-80. doi: 10.1115/1.1470171. J Biomech Eng. 2002. PMID: 12071261
-
Model Properties and Clinical Application in the Finite Element Analysis of Knee Joint: A Review.Orthop Surg. 2024 Feb;16(2):289-302. doi: 10.1111/os.13980. Epub 2024 Jan 4. Orthop Surg. 2024. PMID: 38174410 Free PMC article. Review.
Cited by
-
The KneeKG system: a review of the literature.Knee Surg Sports Traumatol Arthrosc. 2012 Apr;20(4):633-8. doi: 10.1007/s00167-011-1867-4. Epub 2012 Jan 4. Knee Surg Sports Traumatol Arthrosc. 2012. PMID: 22215077 Review.
-
Peak stresses shift from femoral tunnel aperture to tibial tunnel aperture in lateral tibial tunnel ACL reconstructions: a 3D graft-bending angle measurement and finite-element analysis.Knee Surg Sports Traumatol Arthrosc. 2018 Feb;26(2):508-517. doi: 10.1007/s00167-017-4739-8. Epub 2017 Nov 9. Knee Surg Sports Traumatol Arthrosc. 2018. PMID: 29124289
-
Biomechanical influence of lateral meniscal allograft transplantation on knee joint mechanics during the gait cycle.J Orthop Surg Res. 2019 Sep 5;14(1):300. doi: 10.1186/s13018-019-1347-y. J Orthop Surg Res. 2019. PMID: 31488183 Free PMC article.
-
High Tibial Osteotomy: Review of Techniques and Biomechanics.J Healthc Eng. 2019 May 2;2019:8363128. doi: 10.1155/2019/8363128. eCollection 2019. J Healthc Eng. 2019. PMID: 31191853 Free PMC article. Review.
-
Gait disorder rehabilitation using vision and non-vision based sensors: a systematic review.Bosn J Basic Med Sci. 2012 Aug;12(3):193-202. doi: 10.17305/bjbms.2012.2484. Bosn J Basic Med Sci. 2012. PMID: 22938548 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous