Blood sampling through peripheral venous catheters is reliable for selected basic analytes in children
- PMID: 20566616
- DOI: 10.1542/peds.2009-2920
Blood sampling through peripheral venous catheters is reliable for selected basic analytes in children
Abstract
Objective: The goal was to determine the interchangeability of peripheral venous catheter (PVC) and venipuncture blood sampling (BS).
Methods: Paired blood samples from hospitalized children were obtained through venipuncture and from existing PVCs, following discard of 2 mL of blood. Comparisons of 9 complete blood count indices (white and red blood cell counts, hemoglobin and hematocrit levels, mean corpuscular volume, mean corpuscular hemoglobin level, red blood cell distribution width, platelet count, and mean platelet volume) and 5 basic chemical analysis indices (sodium, potassium, glucose, chloride, and urea levels) were performed, and hemolysis was documented.
Results: Irrespective of gauge, blood samples were obtained successfully from 40 (85.1%) of 47 PVCs, with no abnormal hemolysis. BS through venipuncture took longer than BS from PVCs (175.8 +/- 229.6 vs 104.5 +/- 53.4 seconds; P = .053) and was associated with significantly more distress/crying (73.1% vs 0%; P < .001). There were no significant differences between venipuncture and PVC samples (paired t test). Twenty-one (6%) of 348 pairs analyzed with the Clinical Laboratory Improvement Amendment standards fell outside the range of acceptable variance (8 of 21 aberrations were attributed to glucose measurements). Bland-Altman analysis indicated that, with the exclusion of glucose measurements, BS from PVCs is reliable, with 29 (6.5%) of 448 pairs exceeding the limits of agreement. Of those, 9 cases were clinically significant, but none would have altered clinical management.
Conclusions: PVC sampling was shown to be a pain-reducing method that can be used for children for selected basic analytes. The findings for glucose were unreliable.
Similar articles
-
Accuracy of measurements of hemoglobin and potassium in blood samples from peripheral catheters.Am J Crit Care. 1998 Nov;7(6):439-43. Am J Crit Care. 1998. PMID: 9805118 Clinical Trial.
-
Comparison of laboratory values obtained by phlebotomy versus saline lock devices.Acad Emerg Med. 2007 Jan;14(1):23-7. doi: 10.1197/j.aem.2006.06.053. Epub 2006 Nov 10. Acad Emerg Med. 2007. PMID: 17099189
-
Comparison of two blood sampling methods in anticoagulation therapy: venipuncture and peripheral venous catheter.J Clin Nurs. 2008 Feb;17(3):386-93. doi: 10.1111/j.1365-2702.2006.01858.x. Epub 2007 Mar 30. J Clin Nurs. 2008. PMID: 17394539
-
Harmonization of animal clinical pathology testing in toxicity and safety studies. The Joint Scientific Committee for International Harmonization of Clinical Pathology Testing.Fundam Appl Toxicol. 1996 Feb;29(2):198-201. Fundam Appl Toxicol. 1996. PMID: 8742316 Review.
-
Comparisons of laboratory results between two blood samplings: Venipuncture versus peripheral venous catheter-A systematic review with meta-analysis.J Clin Nurs. 2019 Oct;28(19-20):3416-3429. doi: 10.1111/jocn.14918. Epub 2019 Jun 10. J Clin Nurs. 2019. PMID: 31112315
Cited by
-
Current Methods of Haemolysis Detection and Reporting as a Source of Risk to Patient Safety: a Narrative Review.Clin Biochem Rev. 2016 Dec;37(4):143-151. Clin Biochem Rev. 2016. PMID: 28167844 Free PMC article. Review.
-
A cross-sectional study to compare two blood collection methods: direct venous puncture and peripheral venous catheter.BMJ Open. 2014 Feb 27;4(2):e004250. doi: 10.1136/bmjopen-2013-004250. BMJ Open. 2014. PMID: 24578539 Free PMC article.
-
Relationship of Common Vascular Anatomy to Cannulated Catheters.Int J Vasc Med. 2017;2017:5157914. doi: 10.1155/2017/5157914. Epub 2017 Dec 19. Int J Vasc Med. 2017. PMID: 29410917 Free PMC article.
-
Comparison of biochemical and hematologic values obtained via jugular venipuncture and peripheral intravenous catheters in dogs.J Vet Intern Med. 2022 Sep;36(5):1628-1640. doi: 10.1111/jvim.16518. Epub 2022 Aug 27. J Vet Intern Med. 2022. PMID: 36053877 Free PMC article.
-
Reliability of blood tests taken from the peripheral intravenous catheter.Medicine (Baltimore). 2022 Jul 15;101(28):e29268. doi: 10.1097/MD.0000000000029268. Medicine (Baltimore). 2022. PMID: 35839005 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical