Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Dec;51(12):6514-8.
doi: 10.1167/iovs.10-5580. Epub 2010 Jun 23.

Corneal hysteresis and visual field asymmetry in open angle glaucoma

Affiliations

Corneal hysteresis and visual field asymmetry in open angle glaucoma

Aashish Anand et al. Invest Ophthalmol Vis Sci. 2010 Dec.

Abstract

Purpose: To investigate the association between corneal biomechanical parameters and asymmetric primary open angle glaucoma (POAG) using the Ocular Response Analyzer (ORA).

Methods: In a prospective cross-sectional study, ORA parameters were measured in 117 POAG patients with asymmetric visual fields (VF). The asymmetry in VF was defined as a five point difference between the eyes using the Advanced Glaucoma Intervention Study (AGIS) scoring system. Subjects with previous intraocular or refractive surgery, ocular comorbidities and diabetes were excluded.

Results: In worse eyes, mean AGIS scores were significantly higher (8.1 ± 4.3 vs. 1.0 ± 1.6; P < 0.001) and mean corneal hysteresis (CH) was significantly lower (8.2 ± 1.9 vs. 8.9 ± 1.9 mm Hg; P < 0.001). Median ORA-corrected intraocular pressure was higher in the worse eyes (IOP(cc), 17.4 mm Hg vs. 16.9 mm Hg; P < 0.001). Worse eyes had a slightly lower mean corneal resistance factor (P = 0.04) and more myopic mean spherical equivalent (P = 0.02). No difference was seen in the central corneal thickness (CCT; P = 0.63) and Goldmann applanation tonometry (GAT; P = 0.32). On multivariate analysis, only CH retained an association with the worse eye (odds ratio, 25.9; 95% confidence interval, 10.1-66.5). ROC curves showed that only CH and IOP(cc) had a discriminative ability for the eye with worse VF (AUC, 0.82 and 0.70, respectively).

Conclusions: Asymmetric POAG was associated with asymmetry in ORA parameters but not in CCT and GAT. Lower CH was associated with worse eyes independently of its effect on IOP measurement and had the best discriminability for the eye with the worse VF.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources