Utility of second-look ultrasound in the management of incidental enhancing lesions detected by breast MR imaging
- PMID: 20574702
- DOI: 10.1007/s11547-010-0561-9
Utility of second-look ultrasound in the management of incidental enhancing lesions detected by breast MR imaging
Abstract
Purpose: To assess the utility of second-look ultrasound (US) for identifying and characterising incidental enhancing lesions detected by breast magnetic resonance imaging (MRI).
Materials and methods: From among 655 consecutive breast MRI studies, 62 lesions (MRI visible, nonpalpable, occult at first-look US and mammography) were recommended for second-look US. MRI enhancement of lesions was mass-like in 59 cases (95%) and non-mass-like in three (5%). Forty-two lesions (68%) were ≤10 mm; only three lesions (5%) were >20 mm. Of all lesions, the Breast Imaging Reporting and Data System (BI-RADS) MRI category was highly suggestive of malignancy in six cases (10%), suspicious abnormality in 33 (53%) and probably benign in 23 (37%). The correlation between MRI lesion appearance, lesion size, histopathology findings and detection rate at second-look US were analysed. The reference standard was histopathology and/or follow-up (range 18-24 months). Statistical analysis was performed with the Fisher exact test.
Results: Second-look US identified 44 out of 62 (71%) lesions depicted at MRI. The detection rate at second-look US was higher for mass-like MRI lesions (75%) than non-mass-like lesions (0%), for lesion size >10mm (90%) and for BI-RADS 4 lesions (88%). Second-look US-guided biopsy detected 12 out of 17 (71%) malignant lesions. There was no correlation between the likelihood of carcinoma and the presence of a sonographic correlate.
Conclusions: Second-look US is a reliable problem-solving tool in identifying and characterising most incidental MRI findings. It contributes to accurately selecting the cases in which MRI-guided biopsy is required.
Similar articles
-
Incidental enhancing lesions found on preoperative breast MRI: management and role of second-look ultrasound.Radiol Med. 2011 Sep;116(6):886-904. doi: 10.1007/s11547-011-0630-8. Epub 2011 Feb 1. Radiol Med. 2011. PMID: 21293943 English, Italian.
-
Real-time MRI navigated US: role in diagnosis and guided biopsy of incidental breast lesions and axillary lymph nodes detected on breast MRI but not on second look US.Eur J Radiol. 2014 Jun;83(6):942-950. doi: 10.1016/j.ejrad.2014.03.006. Epub 2014 Mar 22. Eur J Radiol. 2014. PMID: 24725672
-
MR-directed ("Second-Look") ultrasound examination for breast lesions detected initially on MRI: MR and sonographic findings.AJR Am J Roentgenol. 2010 Feb;194(2):370-7. doi: 10.2214/AJR.09.2707. AJR Am J Roentgenol. 2010. PMID: 20093598
-
Third-look contrast-enhanced ultrasonography plus needle biopsy for differential diagnosis of magnetic resonance imaging-only detected breast lesions.J Med Ultrason (2001). 2024 Oct;51(4):599-604. doi: 10.1007/s10396-023-01298-8. Epub 2023 Mar 11. J Med Ultrason (2001). 2024. PMID: 36905491 Free PMC article. Review.
-
MRI-detected breast lesions: clinical implications and evaluation based on MRI/ultrasonography fusion technology.Jpn J Radiol. 2019 Oct;37(10):685-693. doi: 10.1007/s11604-019-00866-8. Epub 2019 Sep 5. Jpn J Radiol. 2019. PMID: 31486968 Review.
Cited by
-
Second-look ultrasonography for MRI-detected suspicious breast lesions in patients with breast cancer.Ultrasonography. 2015 Apr;34(2):125-32. doi: 10.14366/usg.14046. Epub 2014 Dec 18. Ultrasonography. 2015. PMID: 25623054 Free PMC article.
-
Utility and Diagnostic Performance of Automated Breast Ultrasound System in Evaluating Pure Non-Mass Enhancement on Breast Magnetic Resonance Imaging.Korean J Radiol. 2020 Nov;21(11):1210-1219. doi: 10.3348/kjr.2019.0881. Epub 2020 Jul 22. Korean J Radiol. 2020. PMID: 32729267 Free PMC article.
-
Incidental enhancing lesions found on preoperative breast MRI: management and role of second-look ultrasound.Radiol Med. 2011 Sep;116(6):886-904. doi: 10.1007/s11547-011-0630-8. Epub 2011 Feb 1. Radiol Med. 2011. PMID: 21293943 English, Italian.
-
MR-guided stereotactic breast biopsy using a mixed ferromagnetic-nonmagnetic coaxial system with 12- to 18-gauge needles: clinical experience and long-term outcome.Radiol Med. 2013 Oct;118(7):1137-48. doi: 10.1007/s11547-013-0954-7. Epub 2013 Jun 25. Radiol Med. 2013. PMID: 23801401
-
BI-RADS 3 Assessment on MRI: A Lesion-Based Review for Breast Radiologists.J Breast Imaging. 2022 Jun 28;4(5):460-473. doi: 10.1093/jbi/wbac032. eCollection 2022 Sep-Oct. J Breast Imaging. 2022. PMID: 36247094 Free PMC article. Review.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical