Safety and efficacy of conversion from external fixation to plate fixation in humeral shaft fractures
- PMID: 20577071
- DOI: 10.1097/BOT.0b013e3181c673a6
Safety and efficacy of conversion from external fixation to plate fixation in humeral shaft fractures
Abstract
Objective: Immediate external fixation and planned conversion to internal fixation of humeral shaft fractures is an option in the treatment of associated severe soft-tissue injuries and severely injured patients. The purpose of this study was to evaluate the outcome and complications of patients who sustained humeral shaft fractures and were treated with initial unilateral external fixation followed by plate fixation.
Design: Retrospective analysis of a prospective database.
Setting: Academic level I trauma center.
Patient/participants: We identified 17 patients treated between June 2003 and August 2007 with immediate unilateral external fixation followed by planned conversion to internal plate fixation. All patients were seen for follow-up until bony union occurred, with a minimum follow-up of 6 months.
Main outcome measurements: Initial patient condition, local and systemic complications, and short-term outcomes were evaluated.
Results: The main reason for immediate placement of an external fixator was multiple trauma in nine patients (damage control orthopedics group); six open fractures with massive soft-tissue injury; one temporarily decreased perfusion to the forearm and hand; and one associated compartment syndrome of the upper arm. The average timing of the conversion to internal fixation was 6.2 (range, 2-14) days from the time of external fixation. There were no iatrogenic nerve injuries after either the external fixation or the conversion to internal fixation. Fifteen of 17 fractures united with an average time to healing of 11.1 (range, 8-14) weeks. Two fractures failed to heal after conversion from external to internal fixation. Both were open fractures from the non-damage control orthopedics group that developed a deep infection. There were no systemic complications after conversion from external to internal fixation.
Conclusions: Immediate external fixation with planned conversion to plate fixation within 2 weeks proved to be a safe and effective approach for the management of humeral shaft fractures in selected patients with multiple injuries or severe soft-tissue injuries that preclude early plate fixation.
Comment in
-
The initial pin site of external fixation conversion to internal fixation.J Orthop Trauma. 2011 Mar;25(3):e31-2. doi: 10.1097/BOT.0b013e31820b8087. J Orthop Trauma. 2011. PMID: 21278602 No abstract available.
Similar articles
-
Comparison of three different treatment modalities in the management of humeral shaft nonunions (plates, unilateral, and circular external fixators).J Orthop Trauma. 2008 Apr;22(4):248-57. doi: 10.1097/BOT.0b013e31816c7b89. J Orthop Trauma. 2008. PMID: 18404034
-
Minimally invasive plate osteosynthesis for humeral shaft fracture: a reproducible technique with the assistance of an external fixator.Arch Orthop Trauma Surg. 2013 May;133(5):649-57. doi: 10.1007/s00402-013-1708-7. Epub 2013 Mar 5. Arch Orthop Trauma Surg. 2013. PMID: 23463256
-
Immediate plate osteosynthesis of open fractures of the humeral shaft.J Trauma. 2010 Sep;69(3):685-90. doi: 10.1097/TA.0b013e3181b02892. J Trauma. 2010. PMID: 20065883
-
Surgical approaches to the humeral shaft.Acta Chir Belg. 1997 Oct;97(5):237-43. Acta Chir Belg. 1997. PMID: 9394965 Review.
-
Principles of tibial fracture management with circular external fixation.Orthop Clin North Am. 2014 Apr;45(2):191-206. doi: 10.1016/j.ocl.2013.11.003. Epub 2014 Jan 23. Orthop Clin North Am. 2014. PMID: 24684913 Review.
Cited by
-
Comparative study of functional outcomes between OTA/AO type C, Gustilo type I/II open fractures and closed fractures of the distal humerus treated by open reduction and internal fixation.BMC Musculoskelet Disord. 2021 Nov 10;22(1):939. doi: 10.1186/s12891-021-04817-1. BMC Musculoskelet Disord. 2021. PMID: 34758812 Free PMC article.
-
Lateral Subcutaneous Locking Compression Plate and Small Incision Reduction for Distal-third Diaphyseal Humerus Fractures.Orthop Surg. 2018 Aug;10(3):218-226. doi: 10.1111/os.12398. Orthop Surg. 2018. PMID: 30152611 Free PMC article.
-
Antegrade Unreamed Locked Intramedullary Nailing in Open Fractures of Shaft of Humerus.J Clin Diagn Res. 2016 Sep;10(9):RC13-RC16. doi: 10.7860/JCDR/2016/19054.8438. Epub 2016 Sep 1. J Clin Diagn Res. 2016. PMID: 27790533 Free PMC article.
-
High Velocity Gunshot Fractures of Humerus: Results of Primary Plate Osteosynthesis.Indian J Orthop. 2020 Nov 6;55(3):714-722. doi: 10.1007/s43465-020-00299-w. eCollection 2021 Jun. Indian J Orthop. 2020. PMID: 33995878 Free PMC article.
-
Humeral shaft fractures.Curr Rev Musculoskelet Med. 2012 Sep;5(3):177-83. doi: 10.1007/s12178-012-9125-z. Curr Rev Musculoskelet Med. 2012. PMID: 22566083 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical