Abstract
A split-thickness hinged scleral flap technique was devised to aid in tube exposure after glaucoma drainage device implantation. This technique resulted in the successful recovery of the tube without reexposure or serious complications in all 3 observed cases. Split-thickness hinged scleral flaps may be an effective surgical technique for the management of repeated tube exposure after glaucoma drainage device implantation.
Similar articles
-
Autologous Partial-thickness Scleral Flap and Donor Corneal Graft in Management of Tube Erosion of Glaucoma Drainage Device.J Glaucoma. 2019 Apr;28(4):347-351. doi: 10.1097/IJG.0000000000001186. J Glaucoma. 2019. PMID: 30628994
-
Comparison of trabeculectomy with Ex-PRESS miniature glaucoma device implanted under scleral flap.J Glaucoma. 2007 Jan;16(1):14-9. doi: 10.1097/01.ijg.0000243479.90403.cd. J Glaucoma. 2007. PMID: 17224744
-
Ex-PRESS miniature glaucoma device implanted under a scleral flap alone or combined with phacoemulsification cataract surgery.J Glaucoma. 2009 Aug;18(6):488-91. doi: 10.1097/IJG.0b013e31818fb44e. J Glaucoma. 2009. PMID: 19223790
-
[Antihypertensive effect of surgical expansion of the scleral ring in the projection of the ciliary body].Vestn Oftalmol. 2007 Nov-Dec;123(6):55-7. Vestn Oftalmol. 2007. PMID: 18225530 Review. Russian. No abstract available.
-
Management of the late leaking filtration blebs. A report of seven cases and a selective review of the literature.Indian J Ophthalmol. 2001 Dec;49(4):247-54. Indian J Ophthalmol. 2001. PMID: 12930117 Review.
Cited by
-
Initial Clinical Experience with Ahmed Valve in Romania: Five-Year Patient Follow-Up and Outcomes.Bioengineering (Basel). 2024 Aug 12;11(8):820. doi: 10.3390/bioengineering11080820. Bioengineering (Basel). 2024. PMID: 39199778 Free PMC article.
-
Short-term efficacy and safety of A-stream glaucoma shunt: a 6-month study.Eye (Lond). 2025 Jun;39(8):1584-1591. doi: 10.1038/s41433-025-03728-y. Epub 2025 Feb 21. Eye (Lond). 2025. PMID: 39979615 Free PMC article.
-
Tube Exposure Repair.J Curr Glaucoma Pract. 2012 Sep-Dec;6(3):139-42. doi: 10.5005/jp-journals-10008-1121. Epub 2012 Oct 16. J Curr Glaucoma Pract. 2012. PMID: 26997770 Free PMC article.