Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Aug;126(2):137-43.
doi: 10.1016/j.thromres.2010.04.012. Epub 2010 May 23.

Microscopic clot fragment evidence of biochemo-mechanical degradation effects in thrombolysis

Affiliations

Microscopic clot fragment evidence of biochemo-mechanical degradation effects in thrombolysis

Franci Bajd et al. Thromb Res. 2010 Aug.

Abstract

Introduction: Although fibrinolytic treatment has been used for decades, the interactions between the biochemical mechanisms and the mechanical forces of the streaming blood remain incompletely understood. Analysis of the blood clot surface in vitro was employed to study the concomitant effect of blood plasma flow and recombinant tissue plasminogen activator (rt-PA) on the degradation of retracted, non-occlusive blood clots. Our hypothesis was that a faster tangential plasma flow removed larger fragments and resulted in faster overall thrombolysis.

Materials and methods: Retracted model blood clots were prepared in an optical microscopy chamber and connected to an artificial perfusion system with either no-flow, or plasma flow with a velocity of 3 cm/s or 30 cm/s with or without added rt-PA at 2 microg/ml. The clot surface was dynamically imaged by an optical microscope for 30 min with 15s intervals.

Results: The clot fragments removed during rt-PA mediated thrombolysis ranged in size from that of a single red blood cell to large agglomerates composed of more than a thousand red blood cells bound together by partly degraded fibrin. The average and the largest discrete clot area change between images in adjacent time frames were significantly higher with the faster flow than with the slow flow (14,000 microm(2) and 160,000 microm(2) vs. 2200 microm(2) and 10,600 microm(2)).

Conclusions: On the micrometer scale, thrombolysis consists of sequential removal of clot fragments from the clot surface. With increasing tangential plasma flow velocity, the size of the clot fragments and the overall rate of thrombolysis increases.

PubMed Disclaimer

Substances

LinkOut - more resources