Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Sep;120(9):1738-43.
doi: 10.1002/lary.21020.

Robotic surgery of the infratemporal fossa utilizing novel suprahyoid port

Affiliations

Robotic surgery of the infratemporal fossa utilizing novel suprahyoid port

Ryan R McCool et al. Laryngoscope. 2010 Sep.

Abstract

Objectives/hypothesis: To develop a minimally invasive technique for robotic access to the infratemporal fossa and describe use of a novel suprahyoid port placement.

Study design: A cadaveric study to assess feasibility of robotic dissection of the infratemporal fossa using a novel, midline suprahyoid port placement.

Methods: Six complete and two partial dissections of the infratemporal fossa were carried out on one fixed and three fresh cadaveric heads using the da Vinci surgical robot (Intuitive Surgical, Inc., Sunnyvale, CA). The suprahyoid port site was utilized to place one robotic arm into the vallecula. The second arm and 30 degrees camera were placed transorally, and dissections were performed through the lateral pharyngeal wall and into the infratemporal fossa with identification and preservation of the lingual nerve, inferior alveolar nerve, internal and external carotid arteries, jugular vein, and cranial nerves IX-XII. Surgical clips were placed at the extent of dissection, and computed tomography (CT) imaging was obtained after dissections.

Results: The transoral and midline suprahyoid port sites provide excellent access to the infratemporal fossa. The midline port site has excellent utility for accessing wide areas of the skull base bilaterally. CT imaging shows surgical clips placed successfully at the skull base foramina of major neurovascular structures.

Conclusions: Robotic surgery offers several advantages over traditional endoscopic surgery with the addition of tremor-free, two-handed technique and microscopic three-dimensional visualization. A midline suprahyoid port placement provides minimally invasive access for excellent exposure of the infratemporal fossa bilaterally.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms

LinkOut - more resources