Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2010 Aug;31(15):1836-44.
doi: 10.1093/eurheartj/ehq234. Epub 2010 Jun 28.

Highly sensitive troponin T assay in normotensive patients with acute pulmonary embolism

Affiliations
Multicenter Study

Highly sensitive troponin T assay in normotensive patients with acute pulmonary embolism

Mareike Lankeit et al. Eur Heart J. 2010 Aug.

Abstract

Aims: To assess the role of cardiac troponin T (cTnT) levels on admission using a new, highly sensitive assay (hsTnT) in the risk assessment of normotensive patients with acute pulmonary embolism (PE).

Methods and results: We prospectively studied 156 consecutive normotensive patients with confirmed PE. The prognostic value of hsTnT at baseline was compared with the conventional cTnT troponin assay and with N-terminal pro-brain natriuretic peptide concentrations. Long-term follow-up was available for 153 patients (98.1%). Highly sensitive troponin T values ranged from 0.001 to 357.2 pg/mL [median 27.2 (25th-75th percentile 9.4-69.4) pg/mL]. Overall, 100 patients (64%) had hsTnT > or =14 pg/mL. Baseline hsTnT was higher in patients with an adverse 30-day outcome (> or =1: death, need for catecholamines, endotracheal intubation, or cardiopulmonary resuscitation) compared with an uncomplicated course [71.7 (35.5-117.9) vs. 26.4 (9.2-68.2) pg/mL; P = 0.027]. The cut-off value of 14 pg/mL showed an excellent prognostic sensitivity and negative predictive value (both 100%). In comparison, as many as 50% of the patients with an adverse early outcome would have been misclassified as low risk by cTnT (cut-off 0.03 ng/mL). Logistic regression indicated a two-fold increase in the risk of an adverse outcome for each increase of hsTnT by 1SD of the natural logarithm (P = 0.037). Patients with elevated hsTnT levels had a reduced probability of long-term survival (P = 0.029 by log-rank); by Cox's regression analysis, hsTnT was the only laboratory biomarker predicting an elevated risk of death over the long term.

Conclusion: Highly sensitive troponin T assays may be capable of improving risk stratification of non-high-risk PE.

PubMed Disclaimer