[A comparison of autologous transfusion procedures in hip surgery]
- PMID: 2058822
[A comparison of autologous transfusion procedures in hip surgery]
Abstract
The risks associated with transfusion can be minimized with autologous blood. The efficiency of preoperative deposit, preoperative hemodilution and intra- and postoperative autotransfusion in reducing homologous transfusions has been demonstrated. There seem to be few studies, however, that compared the different methods of autologous transfusion. This study was designed to evaluate the comparative efficiency of these methods. PATIENTS AND METHODS. Sixty-four patients scheduled for total hip arthroplasty were randomly divided into four groups: group I--preoperative autologous deposit: group II--preoperative hemodilution; group III--intra- and postoperative autotransfusion; group IV--control. Preoperative autologous donations were stored in CPDA-1 buffer. Three units of 450 ml were requested. A predonation hemoglobin (Hb) concentration of 11 g dl was required. Surgery was carried out in the 5th week after the first donation. Preoperative hemodilution to Hb 9 g/dl was carried out after induction of anesthesia and initial circulatory stabilization. A cell separator was used for intra- and postoperative autotransfusion. Postoperative autotransfusion of drainage blood was continued until 6 h after the beginning of the operation. Polygeline was used for volume resuscitation. If the Hb concentration fell below 9 g/dl in the operating room and intensive care unit or below 10 g/dl in the general ward, autologous blood or homologous packed red cells were transfused. Autologous blood collected with the cell separator was retransfused at the end of the operation and after the autotransfusion period irrespective of the actual Hb concentration. RESULTS. The general data of the patients, blood loss, and Hb concentration at the beginning of the study and postoperatively were comparable in the four groups. Homologous transfusion requirements amounted to 0 (0-1250) ml (median, range) packed red cells in group I (preoperative deposit). 500 (0-2000) ml in group II (hemodilution), 125 (0-1000) ml in group III (autotransfusion) and to 500 (0-1500) ml in group IV (control). In group I 14 of 16 patients, in group II 1 of 16, in group III 8 of 16 patients, in group IV 5 of 15 patients did not require homologous transfusion. The difference between group I and IV was significant (p = 0.004 and p = 0.003). Global coagulation tests, antithrombin III, and total serum protein were comparable in the four groups. DISCUSSION. The efficiency of preoperative hemodilution to reduce homologous transfusion requirements is limited]. In the present study, as in two other recent studies, hemodilution did not reduce homologous transfusion requirements. Autotransfusion with a cell separator can save approximately 50% of the erythrocytes lost during hip arthroplasty and 70% of the drainage loss. The homologous transfusion requirements for the autotransfused group reported here were less than in the control group; the difference, however, was not statistically significant. Patients participating in preoperative autologous deposit did not require homologous blood for hip arthroplasty in 62%-70% of cases in other investigations; in the present study 88% of the patients did not require homologous blood. CONCLUSION. Under the conditions studied, preoperative autologous deposit was the most efficient method of autologous transfusion for hip arthroplasty. It should be employed primarily.
Similar articles
-
[Preoperative autologous blood deposit and liquid storage for replacement arthroplasty].Anaesthesist. 1989 Sep;38(9):480-9. Anaesthesist. 1989. PMID: 2589631 German.
-
[Autologous transfusion in total hip endoprosthesis--a clinical concept].Z Orthop Ihre Grenzgeb. 1997 May-Jun;135(3):252-7. doi: 10.1055/s-2008-1039589. Z Orthop Ihre Grenzgeb. 1997. PMID: 9334081 German.
-
[Mannheim concept of preoperative autologous blood donation and perioperative autologous blood transfusion in hip endoprosthesis surgery].Z Orthop Ihre Grenzgeb. 2000 Jul-Aug;138(4):311-7. doi: 10.1055/s-2000-10154. Z Orthop Ihre Grenzgeb. 2000. PMID: 11033898 German.
-
[The safety of preoperative mechanical autologous plasma donation].Beitr Infusionsther. 1991;28:322-30. Beitr Infusionsther. 1991. PMID: 1725648 Review. German.
-
Autotransfusion with intra- and postoperative blood recovery in prosthetic hip surgery. A study conducted on 1368 cementless prostheses.Chir Organi Mov. 1997 Jul-Sep;82(3):249-61. Chir Organi Mov. 1997. PMID: 9494242 Review. English, Italian.
Cited by
-
Cell salvage for minimising perioperative allogeneic blood transfusion.Cochrane Database Syst Rev. 2010 Apr 14;2010(4):CD001888. doi: 10.1002/14651858.CD001888.pub4. Cochrane Database Syst Rev. 2010. Update in: Cochrane Database Syst Rev. 2023 Sep 8;9:CD001888. doi: 10.1002/14651858.CD001888.pub5. PMID: 20393932 Free PMC article. Updated.
-
Pre-operative autologous blood donation: clinical parameters and efficacy.Blood Transfus. 2011 Jan;9(1):10-8. doi: 10.2450/2010.0088-10. Blood Transfus. 2011. PMID: 21235851 Free PMC article. Review. No abstract available.
-
Cell salvage for minimising perioperative allogeneic blood transfusion in adults undergoing elective surgery.Cochrane Database Syst Rev. 2023 Sep 8;9(9):CD001888. doi: 10.1002/14651858.CD001888.pub5. Cochrane Database Syst Rev. 2023. PMID: 37681564 Free PMC article.
-
Recommendations for the transfusion management of patients in the peri-operative period. III. The post-operative period.Blood Transfus. 2011 Jul;9(3):320-35. doi: 10.2450/2011.0076-10. Epub 2011 Apr 20. Blood Transfus. 2011. PMID: 21627922 Free PMC article. No abstract available.
-
Intraoperative hemorrhage in revision total hip arthroplasty: a retrospective single-center study.J Anesth. 2019 Jun;33(3):399-407. doi: 10.1007/s00540-019-02644-2. Epub 2019 Apr 29. J Anesth. 2019. PMID: 31037365
Publication types
MeSH terms
LinkOut - more resources
Medical