Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Jul 30;1217(31):5021-5.
doi: 10.1016/j.chroma.2010.05.060. Epub 2010 Jun 4.

Preconcentration sensitive determination of pyrethroid insecticides in environmental water samples with solid phase extraction with SiO2 microspheres cartridge prior to high performance liquid chromatography

Affiliations

Preconcentration sensitive determination of pyrethroid insecticides in environmental water samples with solid phase extraction with SiO2 microspheres cartridge prior to high performance liquid chromatography

Qingxiang Zhou et al. J Chromatogr A. .

Abstract

Present study developed a new method for the sensitive determination of pyrethroid insecticides with solid phase extraction in combination with high performance liquid chromatography and UV detector. SiO(2) microspheres, a new SiO(2) based material, was investigated for the enrichment ability and applicability as the solid phase extraction sorbent. Four pyrethroid pesticides such as fenpropathrin, cyhalothrin, fenvalevate and biphenthrin were used as the target analytes. Parameters that maybe influence the extraction efficiency such as the eluent type and its volume, sample flow rate, sample pH, and the sample volume were optimized in detail, and the optimal conditions were as followed: sample volume, 100mL; concentration of methanol, 30%; acetone volume, 5mL; sample flow rate, 4.2mLmin(-1); sample pH, 7. The experimental results indicated that there was good linearity in the concentration range of 0.1-50microgL(-1) except biphenthrin in the range of 0.05-25microgL(-1). The detection limits for fenpropathrin, cyhalothrin, fenvalevate and biphenthrin were in the range of 0.02-0.08microgL(-1). The intra-day and day to day precisions (RSDs, n=6) were in the ranges of 2.6-4.4% and 5.3-7.2%, respectively. The method was validated with five real environmental water samples, and all these results proved that proposed method could be used as a good alternative for the routine analysis for such pollutants in environmental samples.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources