Dedicated cardiac cameras: a new option for nuclear myocardial perfusion imaging
- PMID: 20593283
- DOI: 10.1007/s00259-010-1526-x
Dedicated cardiac cameras: a new option for nuclear myocardial perfusion imaging
Comment on
-
Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera.Eur J Nucl Med Mol Imaging. 2010 Aug;37(9):1710-21. doi: 10.1007/s00259-010-1441-1. Epub 2010 Apr 11. Eur J Nucl Med Mol Imaging. 2010. PMID: 20383705 Free PMC article. Clinical Trial.
Similar articles
-
Do we need dedicated cardiac SPECT systems?J Nucl Cardiol. 2021 Aug;28(4):1331-1333. doi: 10.1007/s12350-019-01921-7. Epub 2019 Oct 24. J Nucl Cardiol. 2021. PMID: 31650495 No abstract available.
-
Cardiac dedicated ultrafast SPECT cameras: new designs and clinical implications.J Nucl Med. 2011 Feb;52(2):210-7. doi: 10.2967/jnumed.110.081323. Epub 2011 Jan 13. J Nucl Med. 2011. PMID: 21233190 Review.
-
Cardiac positron emission tomography imaging.Semin Nucl Med. 2005 Jan;35(1):17-36. doi: 10.1053/j.semnuclmed.2004.09.002. Semin Nucl Med. 2005. PMID: 15645392 Review.
-
Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validation.Eur J Nucl Med Mol Imaging. 2010 Apr;37(4):773-8. doi: 10.1007/s00259-009-1375-7. Epub 2010 Jan 27. Eur J Nucl Med Mol Imaging. 2010. PMID: 20107783
-
SPECT Myocardial Perfusion Reserve in Patients with Multivessel Coronary Disease: Correlation with Angiographic Findings and Invasive Fractional Flow Reserve Measurements.J Nucl Med. 2015 Nov;56(11):1712-7. doi: 10.2967/jnumed.114.143164. Epub 2015 Sep 3. J Nucl Med. 2015. PMID: 26338893
Cited by
-
A study to quantify the effect of patient motion and develop methods to detect and correct for motion during myocardial perfusion imaging on a CZT solid-state dedicated cardiac camera.J Nucl Cardiol. 2016 Jun;23(3):514-26. doi: 10.1007/s12350-015-0314-1. Epub 2015 Dec 18. J Nucl Cardiol. 2016. PMID: 26684196
-
Novel 99mTc(III)-azide complexes [99mTc(N3)(CDO)(CDOH)2B-R] (CDOH2=cyclohexanedione dioxime) as potential radiotracers for heart imaging.Nucl Med Biol. 2016 Nov;43(11):732-741. doi: 10.1016/j.nucmedbio.2016.05.001. Epub 2016 May 9. Nucl Med Biol. 2016. PMID: 27632344 Free PMC article.
-
3D iteratively reconstructed spatial resolution map and sensitivity characterization of a dedicated cardiac SPECT camera.J Nucl Cardiol. 2014 Jun;21(3):443-52. doi: 10.1007/s12350-013-9851-7. Epub 2014 Jan 16. J Nucl Cardiol. 2014. PMID: 24429938
-
Comparison between stress myocardial perfusion SPECT recorded with cadmium-zinc-telluride and Anger cameras in various study protocols.Eur J Nucl Med Mol Imaging. 2013 Feb;40(3):331-40. doi: 10.1007/s00259-012-2292-8. Epub 2012 Nov 27. Eur J Nucl Med Mol Imaging. 2013. PMID: 23184308 Clinical Trial.
-
Radiolabeled Cyclic RGD Peptide Bioconjugates as Radiotracers Targeting Multiple Integrins.Bioconjug Chem. 2015 Aug 19;26(8):1413-38. doi: 10.1021/acs.bioconjchem.5b00327. Epub 2015 Aug 3. Bioconjug Chem. 2015. PMID: 26193072 Free PMC article. Review.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources