Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Jul 7;92(7):1635-9.
doi: 10.2106/JBJS.I.01012.

Cemented rotating-platform total knee replacement: a concise follow-up, at a minimum of twenty years, of a previous report

Affiliations

Cemented rotating-platform total knee replacement: a concise follow-up, at a minimum of twenty years, of a previous report

John J Callaghan et al. J Bone Joint Surg Am. .

Abstract

We previously evaluated 119 consecutive total knee arthroplasties performed by a single surgeon in eighty-six patients with use of the cemented LCS (low contact stress) mobile-bearing, rotating-platform system and an all-polyethylene patellar component. The average age of the patients at the time of surgery was seventy years. The patients were contacted as part of their routine follow-up and were asked to participate in this study. The purpose of the present study was to report the updated results at a minimum follow-up of twenty years. Twenty patients (twenty-six knees) were living, and one was lost to follow-up. Three knees required a reoperation (two for periprosthetic fractures and one for infection). No component was revised as a part of the reoperations. No knee required revision since the fifteen-year follow-up evaluation. Osteolysis was present in six knees compared with only three knees at the time of the fifteen-year follow-up. One knee had radiographic signs of femoral component loosening, which was associated with osteolysis. It occurred after the fifteen-year follow-up study. The average range of motion was from 1 degrees of extension to 105 degrees of flexion. The average clinical and functional Knee Society scores were 43 and 49 points, respectively, at the preoperative evaluation and 89 and 67 points at the time of the final follow-up. We concluded that the cemented LCS rotating-platform knee performed well, with durable clinical and radiographic results at a minimum follow-up of twenty years. However, the prevalence of osteolysis continues to increase with a longer duration of follow-up in these patients.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources