. 2009 Jun 14;4(10):1141-5.
doi: 10.1007/s11671-009-9372-0.

Ultra-sensitivity glucose sensor based on field emitters

Affiliations

Ultra-sensitivity glucose sensor based on field emitters

Huibiao Liu et al. Nanoscale Res Lett. .

Abstract

A new glucose sensor based on field emitter of ZnO nanorod arrays (ZNA) was fabricated. This new type of ZNA field emitter-based sensor shows high sensitivity with experimental limit of detection of 1 nM glucose solution and a detection range from 1 nM to 50 μM in air at room temperature, which is lower than that of glucose sensors based on surface plasmon resonance spectroscopy, fluorescence signal transmission, and electrochemical signal transduction. The new glucose sensor provides a key technique for promising consuming application in biological system for detecting low levels of glucose on single cells or bacterial cultures.

Keywords: Field emitter; Glucose sensor; High sensitivity; ZnO nanorod arrays.

PubMed Disclaimer

Figures

Figure 1
Figure 1
SEM images of ZNA:aTop view,bcross-section view
Figure 2
Figure 2
Field emission J–Ecurvesathe ZNA immersing in the glucose concentration from 1 to 500 nM in 6 mM PBS buffer solution and 10 U μL−1glucose oxidase with a pH value of 5.8.bThe control experiments, the ZNA immersing 6 mM PBS buffer solution, 1 mM glucose in 6 mM PBS buffer solution, 10 U μL−1glucose oxidase in 6 mM PBS buffer solution, respectively, with a pH value of 5.8
Figure 3
Figure 3
aPlot of change resistance (R) as a function of concentrations (M) from 1 nM to 50 μM in 6 mM PBS buffer solution and 10 U μL−1glucose oxidase with a pH value of 5.8.bDependence relation between response sensitivity and glucose concentrations
Figure 4
Figure 4
A schematic illustration of the ZNA field emitter-based glucose sensor operating principles

Similar articles

References

    1. Rakow NA, Suslick KS. Nature. 2000. p. 710. COI number [1:CAS:528:DC%2BD3cXmt1CgsLw%3D]; Bibcode number [2000Natur.406..710R] - DOI - PubMed
    1. Lee B, Perez-Luna VH. Anal. 2005. p. 7204. COI number [1:CAS:528:DC%2BD2MXhtFSjtrnN] - DOI - PubMed
    1. Aslan K, Lakowicz JR, Geddes CD. Anal. 2005. p. 2007. COI number [1:CAS:528:DC%2BD2MXhtFeht7c%3D] - DOI - PMC - PubMed
    1. Ge X-D, Tolosa L, Rao G. Anal. 2004. p. 1403. COI number [1:CAS:528:DC%2BD2cXksFChtw%3D%3D] - DOI - PubMed
    1. Meadows DL, Schultz JS. Talanta. 1988. p. 145. COI number [1:CAS:528:DyaL1cXitFygtL8%3D] - DOI - PubMed

LinkOut - more resources