New and unconventional approaches for advancing resolution in biological transmission electron microscopy by improving macromolecular specimen preparation and preservation
- PMID: 20598558
- DOI: 10.1016/j.micron.2010.05.006
New and unconventional approaches for advancing resolution in biological transmission electron microscopy by improving macromolecular specimen preparation and preservation
Abstract
Resolution in transmission electron microscopy (TEM) now is limited by the properties of specimens, rather than by those of instrumentation. The long-standing difficulties in obtaining truly high-resolution structure from biological macromolecules with TEM demand the development, testing, and application of new ideas and unconventional approaches. This review concisely describes some new concepts and innovative methodologies for TEM that deal with unsolved problems in the preparation and preservation of macromolecular specimens. The selected topics include use of better support films, a more protective multi-component matrix surrounding specimens for cryo-TEM and negative staining, and, several quite different changes in microscopy and micrography that should decrease the effects of electron radiation damage; all these practical approaches are non-traditional, but have promise to advance resolution for specimens of biological macromolecules beyond its present level of 3-10 Å (0.3-1.0 nm). The result of achieving truly high resolution will be a fulfillment of the still unrealized potential of transmission electron microscopy for directly revealing the structure of biological macromolecules down to the atomic level.
Published by Elsevier Ltd.
Similar articles
-
Low voltage high-resolution SEM (LVHRSEM) for biological structural and molecular analysis.Micron. 2011 Feb;42(2):175-85. doi: 10.1016/j.micron.2010.08.008. Epub 2010 Sep 8. Micron. 2011. PMID: 21036051 Review.
-
Obtaining high-resolution images of biological macromolecules by using a cryo-electron microscope with a liquid-helium cooled stage.Micron. 2011 Feb;42(2):100-6. doi: 10.1016/j.micron.2010.08.006. Epub 2010 Sep 8. Micron. 2011. PMID: 20869255 Review.
-
What transmission electron microscopes can visualize now and in the future.J Struct Biol. 2008 Sep;163(3):235-45. doi: 10.1016/j.jsb.2008.05.008. Epub 2008 Jun 18. J Struct Biol. 2008. PMID: 18614377 Review.
-
Cryo-SEM and subsequent TEM examinations of identical neural tissue specimen.Brain Res Brain Res Protoc. 2005 Feb;14(2):100-6. doi: 10.1016/j.brainresprot.2004.12.004. Brain Res Brain Res Protoc. 2005. PMID: 15721815
-
Phase plates for transmission electron microscopy.Methods Enzymol. 2010;481:343-69. doi: 10.1016/S0076-6879(10)81014-6. Methods Enzymol. 2010. PMID: 20887864
Cited by
-
Radiation damage in single-particle cryo-electron microscopy: effects of dose and dose rate.J Synchrotron Radiat. 2011 May;18(Pt 3):398-412. doi: 10.1107/S090904951100820X. Epub 2011 Apr 9. J Synchrotron Radiat. 2011. PMID: 21525648 Free PMC article.
-
The advent of structural biology in situ by single particle cryo-electron tomography.Biophys Rep. 2017;3(1):17-35. doi: 10.1007/s41048-017-0040-0. Epub 2017 May 29. Biophys Rep. 2017. PMID: 28781998 Free PMC article.
-
Real-Time Measurement of the Liquid Amount in Cryo-Electron Microscopy Grids Using Laser Diffraction of Regular 2-D Holes of the Grids.Mol Cells. 2020 Mar 31;43(3):298-303. doi: 10.14348/molcells.2020.2238. Mol Cells. 2020. PMID: 32150795 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources