Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2010 Oct;38(10):820-7.
doi: 10.1016/j.jdent.2010.06.014. Epub 2010 Jul 1.

Comparison of the effect of storage media on shear punch strength of resin luting cements

Affiliations
Randomized Controlled Trial

Comparison of the effect of storage media on shear punch strength of resin luting cements

Rafat Bagheri et al. J Dent. 2010 Oct.

Abstract

Objectives: To measure the shear punch strength of eight resin-containing luting cements before and after immersion in acidic solution and ethanol at different temperatures (37 degrees C and 60 degrees C).

Method: Specimens were prepared from six resin luting cements; Set (SDI), Panavia F (Kuraray), RelyX Veneer (3M/ESPE), VarioloinkII (Ivoclar), Maxcem (Kerr), Nexus2 (Kerr) and two Resin-modified glass-ionomer luting cements (RM-GICs); GC Fuji Plus (GC Corporation), RelyX Luting 2 (3M/ESPE). For each material a total of 114 disc-shaped specimens were prepared. Six specimens were immersed in distilled water for 24 h at 37 degrees C, polished and subjected to baseline measurement for shear punch strength. The remaining 108 specimens were randomly divided into 18 groups of six, and immersed in three solutions; distilled water, 0.01 mol/L lactic acid, and 50% ethanol at 37 degrees C or 60 degrees C, for 1 week, 1 month or 3 months. Specimens were washed, dried and tested for final shear punch strength.

Results: Values were material and solution dependent. Values of Nexus 2 and Rely X Veneer are the highest, and Rely X Luting 2 the lowest. Ethanol and lactic acid specimens showed significantly lower values compared with the distilled water specimens.

Conclusion: The shear punch strengths of the resin-containing luting cements were affected by time and storage solution. While some of the resin luting cements had significantly higher values compared to that of the RM-GICs, there were no significant differences between the RM-GICs and resin cements such as Panavia F and Set.