Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Nov;20(6):1275-85.
doi: 10.1007/s10895-010-0679-0. Epub 2010 Jul 7.

First derivative synchronous fluorescence spectroscopy for the simultaneous determination of sulpiride and mebeverine hydrochloride in their combined tablets and application to real human plasma

Affiliations

First derivative synchronous fluorescence spectroscopy for the simultaneous determination of sulpiride and mebeverine hydrochloride in their combined tablets and application to real human plasma

M Walash et al. J Fluoresc. 2010 Nov.

Abstract

A rapid, simple and highly sensitive first derivative synchronous fluorometric method has been developed for the simultaneous analysis of binary mixture of sulpiride (SUL) and mebeverine hydrochloride (MEB). The method is based upon measurement of the synchronous fluorescence intensity of these drugs at ∆λ = 100 nm in water. The different experimental parameters affecting the fluorescence of the two drugs were carefully studied and optimized. The fluorescence-concentration plots were rectilinear over the range of 0.05-1 µg/mL and 0.2-3.2 µg/mL for SUL and MEB respectively with lower detection limits (LOD) of 0.006 and 0.01 µg/mL and quantification limits (LOQ) of 0.0.02 and 0.05 µg/mL for SUL and MEB, respectively. The proposed method was successfully applied for the determination of the two compounds in synthetic mixtures and in commercial tablets. The high sensitivity attained by the proposed method allowed the determination of both of SUL and MEB metabolite (veratic acid) in real human plasma samples applying second derivative synchronous fluorometric technique. The mean% recoveries (n = 3) for both MEB metabolite (veratic acid) and SUL were 99.82 ± 2.53 and 98.84 ± 6.20 for spiked human plasma respectively, while for real human plasma, the mean% recoveries (n = 3) were 91.49 ± 4.25 and 91.36 ± 8.46 respectively.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Electrophoresis. 2001 Sep;22(15):3203-15 - PubMed
    1. Talanta. 2009 Dec 15;80(2):880-8 - PubMed
    1. Spectrochim Acta A Mol Biomol Spectrosc. 2004 Jul;60(8-9):1769-74 - PubMed
    1. J Chromatogr B Biomed Sci Appl. 2001 Nov 5;763(1-2):157-63 - PubMed
    1. J Pharm Biomed Anal. 1999 Nov;21(3):535-48 - PubMed

LinkOut - more resources