Detection of respiratory tumour motion using intrinsic list mode-driven gating in positron emission tomography
- PMID: 20607534
- DOI: 10.1007/s00259-010-1533-y
Detection of respiratory tumour motion using intrinsic list mode-driven gating in positron emission tomography
Abstract
Purpose: Respiratory motion of organs during PET scans is known to degrade PET image quality, potentially resulting in blurred images, attenuation artefacts and erroneous tracer quantification. List mode-based gating has been shown to reduce these pitfalls in cardiac PET. This study evaluates these intrinsic gating methods for tumour PET scans.
Methods: A total of 34 patients with liver or lung tumours (14 liver tumours and 27 lung tumours in all) underwent a 15-min single-bed list mode PET scan of the tumour region. Of these, 15 patients (8 liver and 11 lung tumours in total) were monitored by a video camera registering a marker on the patient's abdomen, thus capturing the respiratory motion for PET gating (video method). Further gating information was deduced by dividing the list mode stream into 200-ms frames, determining the number of coincidences (sensitivity method) and computing the axial centre of mass of the measured count rates in the same frames (centre of mass method). Additionally, these list mode-based methods were evaluated using only coincidences originating from the tumour region by segmenting the tumour in sinogram space (segmented sensitivity/centre of mass method). Measured displacement of the tumours between end-expiration and end-inspiration and the increase in apparent uptake in the gated images served as a measure for the exactness of gating. To estimate the accuracy, a thorax phantom study with moved activity sources simulating small tumours was also performed.
Results: All methods resolved the respiratory motion with varying success. The best results were seen in the segmented centre of mass method, on average leading to larger displacements and uptake values than the other methods. The simple centre of mass method performed worse in terms of displacements due to activities moving into the field of view during the respiratory cycle. Both sensitivity- and video-based methods lead to similar results.
Conclusion: List mode-driven PET gating, especially the segmented centre of mass method, is feasible and accurate in PET scans of liver and lung tumours.
Comment in
-
Current state of data-based gating technology in PET imaging.Eur J Nucl Med Mol Imaging. 2011 Apr;38(4):785. doi: 10.1007/s00259-010-1722-8. Epub 2011 Jan 29. Eur J Nucl Med Mol Imaging. 2011. PMID: 21279351 No abstract available.
Similar articles
-
List mode-driven cardiac and respiratory gating in PET.J Nucl Med. 2009 May;50(5):674-81. doi: 10.2967/jnumed.108.059204. Epub 2009 Apr 16. J Nucl Med. 2009. PMID: 19372491
-
Respiratory-gated PET/CT versus delayed images for the quantitative evaluation of lower pulmonary and hepatic lesions.J Med Imaging Radiat Oncol. 2014;58(3):277-82. doi: 10.1111/1754-9485.12154. Epub 2014 Jan 20. J Med Imaging Radiat Oncol. 2014. PMID: 24438486 Free PMC article.
-
External radioactive markers for PET data-driven respiratory gating in positron emission tomography.Eur J Nucl Med Mol Imaging. 2013 Apr;40(4):602-14. doi: 10.1007/s00259-012-2313-7. Epub 2012 Dec 14. Eur J Nucl Med Mol Imaging. 2013. PMID: 23238525
-
Added Value of Respiratory Gating in Positron Emission Tomography for the Clinical Management of Lung Cancer Patients.Semin Nucl Med. 2022 Nov;52(6):745-758. doi: 10.1053/j.semnuclmed.2022.04.006. Epub 2022 May 25. Semin Nucl Med. 2022. PMID: 35643531 Review.
-
Respiratory Gating and the Performance of PET/CT in Pulmonary Lesions.Curr Radiopharm. 2020;13(3):218-227. doi: 10.2174/1874471013666200317144629. Curr Radiopharm. 2020. PMID: 32183685 Free PMC article. Review.
Cited by
-
Gating Approaches in Cardiac PET Imaging.PET Clin. 2019 Apr;14(2):271-279. doi: 10.1016/j.cpet.2018.12.008. Epub 2019 Feb 1. PET Clin. 2019. PMID: 30826024 Free PMC article. Review.
-
Linear relation between spirometric volume and the motion of cardiac structures: MRI and clinical PET study.J Nucl Cardiol. 2016 Jun;23(3):475-85. doi: 10.1007/s12350-014-0057-4. Epub 2015 Feb 20. J Nucl Cardiol. 2016. PMID: 25698470
-
Motion correction of whole-body PET data with a joint PET-MRI registration functional.Biomed Eng Online. 2014;13 Suppl 1(Suppl 1):S2. doi: 10.1186/1475-925X-13-S1-S2. Epub 2014 Feb 28. Biomed Eng Online. 2014. PMID: 25077815 Free PMC article.
-
Current state of data-based gating technology in PET imaging.Eur J Nucl Med Mol Imaging. 2011 Apr;38(4):785. doi: 10.1007/s00259-010-1722-8. Epub 2011 Jan 29. Eur J Nucl Med Mol Imaging. 2011. PMID: 21279351 No abstract available.
-
Motion detection and amelioration in a dedicated cardiac solid-state CZT SPECT device.Med Biol Eng Comput. 2017 Apr;55(4):663-671. doi: 10.1007/s11517-016-1548-z. Epub 2016 Jul 14. Med Biol Eng Comput. 2017. PMID: 27417733
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical