Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Jul;35(7):1120-5.
doi: 10.1016/j.jhsa.2010.04.002.

Articular surface area of the coronoid process and radial head in elbow extension: surface ratio in cadavers and a computed tomography study in vivo

Affiliations
Comparative Study

Articular surface area of the coronoid process and radial head in elbow extension: surface ratio in cadavers and a computed tomography study in vivo

Seong-Ho Shin et al. J Hand Surg Am. 2010 Jul.

Abstract

Purpose: To quantify the articular surface area ratio of the radial head to the coronoid process to gain a better understanding of the stress distribution across these articulations and possibly to explain the patterns of osteoarthritis that are commonly seen in the elbow.

Methods: Thirty cadaveric elbows were harvested and dissected to allow measurement of the radial head and coronoid process articular surfaces. The articular surface areas were measured using the Image J program (National Institutes of Health, Chicago, IL). Twelve men were recruited for this study, and all received a computed tomography (CT) scan of the elbow. A 3-dimensional image of the proximal radioulnar articular surface was created using volume rendering. All specimens were measured 3 times by 2 observers.

Results: In the cadaveric measurements, the mean area of the radial head articular fossa was 247.3 +/- 52.6 mm(2) (mean +/- SD). The mean area of the medial facet of the coronoid process was 232.29 +/- 36.5 mm(2), and the mean area of the lateral facet was 141.9 +/- 33.3 mm(2). The articular surface area ratio of radial head to coronoid process was 1:1.5. In the CT measurement, the mean area of the radial head articular fossa was 258.9 +/- 26.3 mm(2). The mean area of the coronoid process articular surface was 376.9 +/- 37.0 mm(2). The articular surface area ratio of radial head to coronoid process was 1:1.46.

Conclusions: The ratio of articular surface area of radial head to coronoid process is 1:1.51 in cadavers and 1:1.46 using a CT in vivo, which is the reverse of the reported force transmission ratio across the elbow joint.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources