Pupil tracking with a Hartmann-Shack wavefront sensor
- PMID: 20615024
- DOI: 10.1117/1.3447922
Pupil tracking with a Hartmann-Shack wavefront sensor
Abstract
We present the theoretical background and experimental validation of a pupil tracking method based on measurement of the irradiance centroid of Hartmann-Shack aberrometric images. The experimental setup consists of a Hartmann-Shack (HS) sensor forming over the same camera the images of the eye's pupil and the aberrometric image. The calibration is made by comparing the controlled displacements induced to an artificial eye with the displacements estimated from the centroid of the pupil and of the HS focal plane. The pupil image is also used for validation of the method when operating with human eyes. The experimental results after calibration show a root mean square error of 10.45 mum for the artificial eye and 27, 10, and 6 mum rms for human eyes tested using Hartmann-Shack images, with signal-to-noise ratios of 6, 8, and 11, respectively. The performance of the method is similar to conventional commercial eye trackers. It avoids the need for using separate tracking devices and their associated synchronization problems. This technique can also be used to reprocess present and stored sets of Hartmann-Shack aberrometric images to estimate the ocular movements that occurred during the measurement runs, and, if convenient, to correct the measured aberrations from their influence.
Similar articles
-
Myopic aberrations: impact of centroiding noise in Hartmann Shack wavefront sensing.Ophthalmic Physiol Opt. 2013 Jul;33(4):434-43. doi: 10.1111/opo.12076. Ophthalmic Physiol Opt. 2013. PMID: 23786384
-
Wavefront control in adaptive microscopy using Shack-Hartmann sensors with arbitrarily shaped pupils.Opt Express. 2018 Jan 22;26(2):1655-1669. doi: 10.1364/OE.26.001655. Opt Express. 2018. PMID: 29402037
-
In vivo and in vitro repeatability of Hartmann-Shack aberrometry.J Cataract Refract Surg. 2003 Dec;29(12):2295-301. doi: 10.1016/s0886-3350(03)00655-2. J Cataract Refract Surg. 2003. PMID: 14709289
-
Wave aberration of human eyes and new descriptors of image optical quality and visual performance.J Cataract Refract Surg. 2010 Feb;36(2):313-31. doi: 10.1016/j.jcrs.2009.09.026. J Cataract Refract Surg. 2010. PMID: 20152616 Review.
-
Mr. Guthrie on the Operations for the Formation of an Artificial Pupil, &c.Med Chir Rev J Med Sci Anal Ser. 1820 Jun 1;1(1):71-79. Med Chir Rev J Med Sci Anal Ser. 1820. PMID: 29917364 Free PMC article. Review. No abstract available.
Cited by
-
Eye-pupil displacement and prediction: effects on residual wavefront in adaptive optics retinal imaging.Biomed Opt Express. 2016 Feb 25;7(3):1051-73. doi: 10.1364/BOE.7.001051. eCollection 2016 Mar 1. Biomed Opt Express. 2016. PMID: 27231607 Free PMC article.
-
Retinal adaptive optics imaging with a pyramid wavefront sensor.Biomed Opt Express. 2021 Sep 2;12(10):5969-5990. doi: 10.1364/BOE.438915. eCollection 2021 Oct 1. Biomed Opt Express. 2021. PMID: 34745716 Free PMC article.
-
Adaptive optics retinal imaging with automatic detection of the pupil and its boundary in real time using Shack-Hartmann images.Appl Opt. 2017 Aug 20;56(24):6748-6754. doi: 10.1364/AO.56.006748. Appl Opt. 2017. PMID: 29048013 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources