Multicenter Study
. 2010 Nov;157(5):767-71.e1-3.
doi: 10.1016/j.jpeds.2010.05.043.

Ventilation practices in the neonatal intensive care unit: a cross-sectional study

Collaborators, Affiliations
Multicenter Study

Ventilation practices in the neonatal intensive care unit: a cross-sectional study

Anton H van Kaam et al. J Pediatr. 2010 Nov.

Abstract

Objective: To assess current ventilation practices in newborn infants.

Study design: We conducted a 2-point cross-sectional study in 173 European neonatal intensive care units, including 535 infants (mean gestational age 28 weeks and birth weight 1024 g). Patient characteristics, ventilator settings, and measurements were collected bedside from endotracheally ventilated infants.

Results: A total of 457 (85%) patients were conventionally ventilated. Time cycled pressure-limited ventilation was used in 59% of these patients, most often combined with synchronized intermittent mandatory ventilation (51%). Newer conventional ventilation modes like volume targeted and pressure support ventilation were used in, respectively, 9% and 7% of the patients. The mean tidal volume, measured in 84% of the conventionally ventilated patients, was 5.7 ± 2.3 ml/kg. The mean positive end-expiratory pressure was 4.5 ± 1.1 cmH(2)O and rarely exceeded 7 cmH(2)O.

Conclusions: Time cycled pressure-limited ventilation is the most commonly used mode in neonatal ventilation. Tidal volumes are usually targeted between 4 to 7 mL/kg and positive end-expiratory pressure between 4 to 6 cmH(2)O. Newer ventilation modes are only used in a minority of patients.