Strict actions of the human wrist extensors: A study with an electrical neuromuscular stimulation method
- PMID: 20638861
- DOI: 10.1016/j.jelekin.2010.06.003
Strict actions of the human wrist extensors: A study with an electrical neuromuscular stimulation method
Abstract
Motion and force produced by electrical neuromuscular stimulation (ENS) to each of the extensor carpi radialis longus (ECRL) and brevis (ECRB), and extensor carpi ulnaris (ECU) with the prone (P), semiprone (SP), and supine forearm (S) were studied in ten normal human subjects. Abduction (AB), extension (E), adduction (AD), and flexion (F) directions were represented by, respectively, 0°, 90°, 180°, and 270°. ENS to ECRL, ECRB, and ECU produced motion in direction of, respectively, 60° (mean), 87°, and 205° with P, 66°, 83°, and 166° with SP, and 47°, 66°, and 116° with S to maximal range. Direction/strength (Nm) of force by ENS to ECRL, ECRB, and ECU were, respectively, 54°/1.75, 74°/1.78, and 184°/1.49 with P, 34°/1.65, 63°/1.66, and 152°/1.43 with SP, and 32°/1.66, 70°/1.49, and 147°/1.25 with S. ENS to ECRL exhibited force of 15-20% of maximal E (15-20%Max-E) and 19-29%Max-AB, that to ECRB 24-32%Max-E, and that to ECU 17-30%Max-AD. The force study results suggest that ECRL is an abductor and extensor and ECRB is an extensor rather than an abductor. ECU should be an adductor rather than an extensor with SP and S and an adductor with P. The data must contribute to reconstruct motor functions of paralyzed hands.
Copyright © 2010 Elsevier Ltd. All rights reserved.
Similar articles
-
Co-contraction of the pronator teres and extensor carpi radialis during wrist extension movements in humans.J Electromyogr Kinesiol. 2007 Feb;17(1):80-9. doi: 10.1016/j.jelekin.2005.11.013. Epub 2006 Mar 3. J Electromyogr Kinesiol. 2007. PMID: 16516494
-
Strict actions of the human wrist flexors: A study with an electrical neuromuscular stimulation method.J Electromyogr Kinesiol. 2015 Aug;25(4):689-96. doi: 10.1016/j.jelekin.2015.04.004. Epub 2015 Apr 16. J Electromyogr Kinesiol. 2015. PMID: 25921817
-
Neuromuscular partitioning in the extensor carpi radialis longus and brevis based on intramuscular nerve distribution patterns: A three-dimensional modeling study.Clin Anat. 2012 Apr;25(3):366-72. doi: 10.1002/ca.21246. Epub 2011 Aug 18. Clin Anat. 2012. PMID: 21853467
-
The supination effect of tendon transfer of the flexor carpi ulnaris to the extensor carpi radialis brevis or longus: a cadaveric study.J Hand Surg Am. 1999 Sep;24(5):1091-6. doi: 10.1053/jhsu.1999.1091. J Hand Surg Am. 1999. PMID: 10509290
-
Moment arm and force-generating capacity of the extensor carpi ulnaris after transfer to the extensor carpi radialis brevis.J Hand Surg Am. 1999 Sep;24(5):1083-90. doi: 10.1053/jhsu.1999.1083. J Hand Surg Am. 1999. PMID: 10509289
Cited by
-
A case series of upper extremity reconstructions utilizing partial ECRB and ECRL tendon autografts.J Surg Case Rep. 2024 Aug 14;2024(8):rjae278. doi: 10.1093/jscr/rjae278. eCollection 2024 Aug. J Surg Case Rep. 2024. PMID: 39144104 Free PMC article.
-
Oligosynaptic inhibition mediated by group Ia afferents from flexor digitorum superficialis to wrist flexors in humans.Exp Brain Res. 2018 Jul;236(7):1849-1860. doi: 10.1007/s00221-018-5268-5. Epub 2018 Apr 20. Exp Brain Res. 2018. PMID: 29679107
-
Facilitation from flexor digitorum superficialis to extensor carpi radialis in humans.Exp Brain Res. 2016 Aug;234(8):2235-44. doi: 10.1007/s00221-016-4629-1. Epub 2016 Mar 24. Exp Brain Res. 2016. PMID: 27010723
-
Spatial localization of electromyographic amplitude distributions associated to the activation of dorsal forearm muscles.Front Physiol. 2013 Dec 13;4:367. doi: 10.3389/fphys.2013.00367. eCollection 2013. Front Physiol. 2013. PMID: 24379788 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources