Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Dec;20(12):2844-52.
doi: 10.1007/s00330-010-1888-2. Epub 2010 Jul 17.

Cardiac chamber quantification using magnetic resonance imaging at 7 Tesla--a pilot study

Affiliations

Cardiac chamber quantification using magnetic resonance imaging at 7 Tesla--a pilot study

Florian von Knobelsdorff-Brenkenhoff et al. Eur Radiol. 2010 Dec.

Abstract

Objectives: Interest in cardiovascular magnetic resonance (CMR) at 7 T is motivated by the expected increase in spatial and temporal resolution, but the method is technically challenging. We examined the feasibility of cardiac chamber quantification at 7 T.

Methods: A stack of short axes covering the left ventricle was obtained in nine healthy male volunteers. At 1.5 T, steady-state free precession (SSFP) and fast gradient echo (FGRE) cine imaging with 7 mm slice thickness (STH) were used. At 7 T, FGRE with 7 mm and 4 mm STH were applied. End-diastolic volume, end-systolic volume, ejection fraction and mass were calculated.

Results: All 7 T examinations provided excellent blood/myocardium contrast for all slice directions. No significant difference was found regarding ejection fraction and cardiac volumes between SSFP at 1.5 T and FGRE at 7 T, while volumes obtained from FGRE at 1.5 T were underestimated. Cardiac mass derived from FGRE at 1.5 and 7 T was larger than obtained from SSFP at 1.5 T. Agreement of volumes and mass between SSFP at 1.5 T and FGRE improved for FGRE at 7 T when combined with an STH reduction to 4 mm.

Conclusions: This pilot study demonstrates that cardiac chamber quantification at 7 T using FGRE is feasible and agrees closely with SSFP at 1.5 T.

PubMed Disclaimer

References

    1. Magn Reson Med. 2004 Apr;51(4):799-806 - PubMed
    1. J Magn Reson. 2009 Sep;200(1):161-6 - PubMed
    1. Magn Reson Imaging Clin N Am. 2007 Aug;15(3):449-65, viii - PubMed
    1. Echocardiography. 2007 Feb;24(2):185-93 - PubMed
    1. J Am Coll Cardiol. 2006 Oct 3;48(7):1475-97 - PubMed

LinkOut - more resources